Viscosity 911
Place a quantity of Gel in a suitable plastic container, insert the stopper securely, and allow to stand until the gel is free from air bubbles. Place it in a water bath maintained at a temperature of 25 ± 0.5
until it adjusts to the temperature of the water bath (4 hours or longer). Do not stir the gel while it is in the bath. Remove the specimen from the bath, stir the gel gently for 2 minutes, and without delay, using a rotational viscosimeter, determine the viscosity using a spindle having a cylinder 1.27 cm in diameter and 0.16 cm high attached to a shaft 0.32 cm in diameter, the distance from the top of the cylinder to the lower tip of the shaft being 2.54 cm and the immersion depth being 5.00 cm (No. 3 spindle). Operate the viscosimeter at 12 rpm, and record the scale reading at 1-minute intervals for 4 minutes. Calculate the viscosity, in centipoises, by multiplying the scale reading by 100: the viscosity is between 600 and 170,000 centipoises.
Stannous ion content
Procedure
Transfer an accurately weighed quantity of Gel, equivalent to about 80 mg of stannous fluoride, to a capped plastic vessel equipped for titration in an inert atmosphere. Add a plastic coated stirring bar, 20 mL of recently boiled 3 N hydrochloric acid, and 5 mL of
potassium iodide TS. Close the vessel, purge the system with an oxygen-free inert gas, and titrate immediately with 0.1
N Potassium iodide-iodate adding 2 mL of
starch TS as the endpoint is approached. Calculate the quantity, in mg, of stannous ion (Sn++) in each g of Gel by the formula:
5.935V / W,
in which
V is the volume, in mL, of 0.1 N potassium iodide-iodate consumed; 5.935 is the Sn++ equivalent, in mg, of each mL of 0.1 N potassium iodide-iodate; and
W is the weight, in g, of Gel taken. The quantity, in mg, of stannous ion in each g of Gel is not less than 68.2% of the quantity, in mg, of stannous fluoride in each g of Gel as determined in the
Assay, and is not less than 90.0% of the quantity, in mg, of total tin in each g of Gel as determined in the test for
Total tin content.
Total tin content
Potassium chloride solution
Dissolve 1.91 g of potassium chloride in water to make 100 mL of solution.
Tin stock standard solution
Transfer 1.000 g of tin, accurately weighed, to a 1000-mL volumetric flask, add 200 mL of hydrochloric acid, and swirl to dissolve. Add 200 mL of water, allow to cool, dilute with water to volume, and mix.
Standard preparations
Transfer 5.0, 10.0, and 15.0 mL of Tin stock standard solution to separate 100-mL volumetric flasks, add 1.0 mL of Potassium chloride solution to each flask, dilute with water to volume, and mix. The Standard preparations contain, respectively, 50.0, 100.0, and 150.0 µg of tin per mL.
Test preparation
Transfer an accurately weighed quantity of Gel, equivalent to about 132 mg of stannous fluoride, to a plastic beaker. Add 80 mL of water and 20 mL of hydrochloric acid, and mix. Transfer this mixture to a 1000-mL volumetric flask, add 10.0 mL of Potassium chloride solution, dilute with water to volume, and mix.
Blank
Add 2 mL of hydrochloric acid and 1.0 mL of Potassium chloride solution to a 100-mL volumetric flask, dilute with water to volume, and mix.
Procedure
Concomitantly determine the absorbance of the
Standard preparations, the
Test preparation, and the
Blank at the tin emission line of 235.5 nm, with an atomic absorption spectrophotometer (see
Spectrophotometry and Light-scattering 851) equipped with a tin hollow-cathode lamp and a nitrous oxide-acetylene oxidizing flame, using water to adjust the instrument to zero. Aspirate water into the spectrophotometer before and after each
Standard preparation, the
Test preparation, and the
Blank. Correct the absorbances of the
Standard preparations and the
Test preparation by subtracting the absorbance of the
Blank. Plot the corrected absorbances of the
Standard preparations versus concentration, in µg per mL, of tin, and draw the straight line best fitting the three plotted points. From the graph so obtained, determine the concentration, in µg per mL, of tin in the
Test preparation. Calculate the quantity, in mg, of tin in each g of Gel taken by the formula:
C / W,
in which
C is the concentration, in µg per mL, of tin in the
Test preparation; and
W is the quantity, in g, of Gel taken to prepare the
Test preparation. Use this value to calculate the percentage of stannous ion in the test for
Stannous ion content.
Assay
[NOTEStore all solutions, except the
Buffer solution, in plastic containers.
]
Assay preparation
Transfer an accurately weighed quantity of Gel, equivalent to about 8 mg of stannous fluoride, to a 100-mL volumetric flask, dilute with water to volume, and mix.
Procedure
Proceed as directed for
Procedure in the
Assay under
Sodium Fluoride Oral Solution. Calculate the quantity, in mg, of stannous fluoride (SnF
2) in each g of the Gel taken by the formula:
(156.71 / 38.0)(C / 10W),
in which 156.71 is the molecular weight of stannous fluoride, 38.0 is twice the atomic weight of fluorine;
C is the determined concentration, in µg per mL, of fluoride in the
Assay preparation; and
W is the weight, in g, of the Gel taken.