Assay preparation
Separately dissolve the contents of not less than 5 vials of Gonadorelin for Injection in
Mobile phase to obtain a concentration of 100 µg of gonadorelin per mL. Place the vials in an ultrasonic bath for 5 minutes, and allow to cool at room temperature. Combine the solutions in the vials to obtain the
Assay preparation.
Procedure
Proceed as directed in the
Assay under
Gonadorelin Hydrochloride. Plot the responses of the gonadorelin peaks versus concentration, in mg per mL, of gonadorelin in each of the
Standard preparation. Calculate the quantity of gonadorelin (C
55H
75N
17O
13) in the Gonadorelin for Injection taken for the
Assay preparation by the formula:
(1182.33 / 1255.4)(C)(V + 0.06),
in which 1182.33 and 1255.4 are the molecular weights of gonadorelin and gonadorelin hydrochloride, respectively;
C is the concentration of gonadorelin in the
Assay preparation as obtained from the regression line;
V is the volume, in mL, of
Mobile phase used to prepare the
Assay preparation; and 0.06 is the correction factor for the volume created by the dissolved test specimen.