Packaging and storage
Preserve in tight, well-sealed containers.
Identification
The retention time of the major peak in the chromatogram of the Assay preparation corresponds to that in the chromatogram of the Standard preparation, as obtained in the Assay.
Specific rotation 781S:
between 57
and 63
, calculated on the anhydrous and chloride-free basis.
Test solution:
10 mg per mL, in water.
Water
[NOTEDry all glassware used in the following procedure at 105
for a minimum of 1 hour, and cool in a desiccator at room temperature. Store in a desiccator. Perform as many operations as possible in a low-humidity glove box.
]
Anhydrous methanol
Wash about 150 g of 8- to 17-mesh type 3A molecular sieve with several 100-mL portions of methanol to remove the fine particles. Place the washed molecular sieve in a shallow glass dish, heat in an oven at 350
for 2 hours, and cool in a desiccator. Transfer the dry molecular sieve to a 1-L glass container, add about 700 mL of methanol, insert a stopper, mix, and allow to stand in a desiccator for not less than 48 hours before using.
Standard solutions
Prepare solutions in Anhydrous methanol containing 0.4, 0.8, and 1.2 mg of distilled water per mL.
Test solution
[NOTEPrepare immediately prior to use.] Transfer about 20 mg of Gonadorelin Hydrochloride, accurately weighed, to a vial, place a cap on the vial, add 800 µL of Anhydrous methanol by means of a 1000-µL gas-tight syringe, and swirl to mix.
Chromatographic system (see Chromatography 621)
The gas chromatograph is equipped with a thermal conductivity detector and a 2-mm × 180-cm glass column packed with 80- to 100-mesh support S3. The column temperature is maintained at about 100
, and the injection port and detector temperatures are maintained at 130
. Helium is used as the carrier gas at a flow rate of about 30 mL per minute. Chromatograph the
Standard solution containing 1.2 mg per mL, record the chromatograms, and measure the peak responses as directed for
Procedure: the elution order is water, followed by a broad methanol peak; the retention time of the water peak is between 0.5 and 3 minutes; and the relative standard deviation for not less than three replicate injections is not more than 2.5%.
Procedure
Separately inject equal volumes (1 to 3 µL) of each of the
Standard solutions, Test solution, and
Anhydrous methanol into the chromatograph, and measure the responses for the first (water) and second (methanol) major peaks, correcting the peak areas obtained from the
Test solution and the
Standard solutions against the
Anhydrous methanol blank. Plot the responses of the water peaks versus concentration, in mg per mL, of water in each of the
Standard solutions, and determine the regression line using the least-squares method. The coefficient of variation from the regression line is not more than 3.0%. From the graph so obtained, determine the concentration,
C, in mg per mL, of water in the
Test solution. Calculate the percentage of water in the portion of Gonadorelin Hydrochloride taken by the formula:
80C/W,
in which
W is the weight, in mg, of Gonadorelin Hydrochloride in the
Test solution: not more than 7.0% is found.
Limit of acetate
Mobile phase
To 500 mL of water in a 1-L volumetric flask, add 1 mL of sulfuric acid. Dilute with water to volume, mix, and pass through a membrane filter having a 0.45-µm or finer porosity. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Acetate standard solutions
Dissolve an accurately weighed quantity of sodium acetate trihydrate in Mobile phase to obtain a stock solution having a known concentration of about 0.5 mg per mL. Quantitatively dilute accurately measured volumes of this stock solution with Mobile phase to obtain Standard solutions having known concentrations of about 100, 10, and 1 µg of sodium acetate trihydrate per mL.
Test solution
Transfer about 50 mg of Gonadorelin Hydrochloride, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 205-nm detector and a 6.5-mm × 30-cm column that contains packing L17. The flow rate is about 0.5 mL per minute.
[NOTEDo not allow the flow rate to exceed 0.6 mL per minute. Condition the column for about 60 minutes until a stable baseline is obtained.
] Chromatograph the
Acetate standard solution containing 100 µg of sodium acetate trihydrate per mL, and record the peak responses as directed for
Procedure: the retention time of the acetate peak is between 10 and 16 minutes; the column efficiency is not less than 2000 theoretical plates; the tailing factor is not more than 2; and the relative standard deviation for not less than three replicate injections is not more than 3.0%.
Procedure
Separately inject equal volumes (about 100 µL) of each
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the responses for the major peaks.
[NOTEIf more than five specimens are analyzed, reinject the
Standard solutions before injecting further specimens of the
Test solution.] Plot the responses of the
Standard solutions versus concentration, in µg of sodium acetate trihydrate per mL, and determine the regression line, using the least-squares method. The coefficient of variation from the regression line is not more than 3.0%. From the graph so obtained, determine the concentration,
C, in µg per mL, of sodium acetate trihydrate in the
Test solution. Calculate the percentage of acetate (C
2H
3O
2) in the portion of Gonadorelin Hydrochloride taken by the formula:
(59.03/136.08)(5C/W),
in which 59.03 and 136.08 are the molecular weights of acetate and sodium acetate trihydrate, respectively; and
W is the weight, in mg, of Gonadorelin Hydrochloride in the
Test solution: not more than 1.0% is found.
Chromatographic purity
[NOTEPerform all procedures in a low-humidity glove box. The
Test solution may be stored at room temperature for up to 20 minutes, or at 4
for up to 8 hours.
]
Solution A
Dissolve 13.6 g of monobasic potassium phosphate in water, dilute with water to 2000 mL, and mix. Filter and degas. Adjust with 1 N potassium hydroxide to a pH of 6.5. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Solution B
Use acetonitrile.
Mobile phase
Use variable mixtures of Solution A and Solution B as directed for Chromatographic system.
Standard solutions
Dissolve an accurately weighed quantity of
USP Gonadorelin Hydrochloride RS in and dilute quantitatively with
Solution A to obtain a stock solution having a known concentration of about 1 mg per mL. Quantitatively dilute accurately measured volumes of this stock solution with
Solution A to obtain
Standard solutions having known concentrations of about 40, 5, and 1.5 µg per mL.
Test solution
Dissolve an accurately weighed quantity of Gonadorelin Hydrochloride in Solution A to obtain a solution having a concentration of 1 mg per mL.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 220-nm UV detector and a 4.6-mm × 15-cm column containing 5-µm packing L1, and is programmed to provide variable mixtures of
Solution A and
Solution B, beginning with 100% of
Solution A, changing after 3 minutes to a mixture of 82%
Solution A and 18%
Solution B, maintained at that composition for the next 17 minutes, then changed linearly over the next 10 minutes so that it consists of a mixture of 30%
Solution A and 70%
Solution B at 30 minutes, and maintained at that composition for the next 5 minutes, then changed linearly over the next 3 minutes so that the composition at 38 minutes is again 100%
Solution A. Pump
Solution A through the column at a flow rate of about 1 mL per minute for about 30 minutes or until a stable baseline is obtained, then inject 100 µL of
Solution A, and run the gradient elution program to completion to condition the column. Again inject 100 µL of
Solution A, and run the gradient elution program to completion. Chromatograph the
Standard solution containing 40 µg per mL, and record the peak responses as directed for
Procedure: the retention time for gonadorelin is between 24 and 30 minutes; the column efficiency is not less than 5000 theoretical plates; and the tailing factor is not more than 2.0. If necessary, adjust the flow rate (to between 0.8 and 2 mL per minute) or, alternatively, change (by not more than 3%) the percentages of
Solution A and
Solution B at 3 minutes and at 20 minutes.
Procedure
Separately inject equal volumes (about 100 µL) of Solution A, each of the Standard solutions, and the Test solution into the chromatograph, record the chromatograms, and measure the peak responses. Correct the peak responses, using the chromatogram of Solution A as a blank. Plot the corrected responses of the Standard solutions, and determine the regression line, using the least-squares method. The coefficient of variation from the regression line is not more than 3.0%. From the graph so obtained, determine the concentration of each impurity in the Test solution: not more than 3.0% of any individual impurity is found, and not more than 5.0% of total impurities is found.
Content of chloride
Dissolve 25 mg of Gonadorelin Hydrochloride, accurately weighed, in 1 mL of methanol. Add 10 mL of water and 1 drop of glacial acetic acid, and titrate with 0.01 N silver nitrate VS, determining the endpoint potentiometrically. Perform a blank determination, and make any necessary correction. Each mL of 0.01 N silver nitrate is equivalent to 0.3545 mg of chloride: the chloride content is between 4.0% and 6.0%.
Assay
[NOTEPerform all manipulations involving the weighing of the Gonadorelin Hydrochloride and the Reference Standard in a low-humidity glove box.
]
Buffer solution
Dissolve 6.8 g of monobasic potassium phosphate in water, and dilute with water to 1000 mL. Adjust with 1 N potassium hydroxide to a pH of 6.5.
Mobile phase
Prepare a filtered and degassed mixture of
Buffer solution and acetonitrile (82:18). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparations
Quantitatively dissolve accurately weighed quantities of
USP Gonadorelin Hydrochloride RS in
Mobile phase to obtain solutions having known concentrations of about 0.08 mg per mL, 0.10 mg per mL, and 0.12 mg per mL.
[NOTEThese
Standard preparations may be stored in a refrigerator for 2 months. Remove suitable portions and warm to room temperature before use.
]
Assay preparation
Dissolve an accurately weighed quantity of Gonadorelin Hydrochloride in Mobile phase to obtain a solution containing 0.10 mg per mL.
Identification solution
Mix equal volumes of the Assay preparation and the Standard preparation containing 0.10 mg per mL.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 220-nm detector and a 4.6-mm × 15-cm column that contains 5-µm packing L1. The flow rate is about 1.5 mL per minute.
[NOTECondition the column with
Mobile phase until a stable baseline is obtained.
] Chromatograph about 20 µL of the
Identification solution: the ratio,
RR, of the retention times of the gonadorelin peaks obtained from the
Assay preparation and the
Standard preparation is 1.00 ± 0.05. Chromatograph the
Standard preparation containing 0.08 mg per mL, and record the peak responses as directed for
Procedure: the retention time for gonadorelin is between 8 and 11 minutes; the column efficiency is not less than 900 theoretical plates; the tailing factor is not more than 2.5; and the relative standard deviation for not fewer than three replicate injections is not more than 3.0%.
Procedure
Separately inject equal volumes (about 20 µL) of each of the
Standard preparations and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks.
[NOTEIf more than five specimens are analyzed, reinject the
Standard preparations before injecting further specimens of the
Assay preparation.] Plot the responses of the gonadorelin peaks versus concentration, in mg per mL, of gonadorelin in each of the
Standard preparations, and determine the regression line, using the least-squares method. The coefficient of variation from the regression line is not more than 3.0%. From the graph so obtained, determine the concentration,
C, of gonadorelin in the
Assay preparation. Calculate the percentage of C
55H
75N
17O
13· 2HCl in the portion of Gonadorelin Hydrochloride taken by the formula:
100C.