Related compounds
Cation suppressor regeneration solution:
0.02 M tetrabutylammonium hydroxide.
Mobile phase
Mix 1500 mL of filtered water, 250 mL of filtered methanol, 45 mL of filtered tetrahydrofuran, and 1 mL of hydrochloric acid in a 2000-mL volumetric flask. Leave at room temperature for few minutes, and dilute with water to volume. Mix, and degas. [NOTEAvoid evaporation of tetrahydrofuran during degassing.]
Test solution
Transfer about 25 mg of Vecuronium Bromide, accurately weighed, to a 25-mL volumetric flask. Add 0.5 mL of acetonitrile, dilute with 0.0025 N hydrochloric acid to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid-ion chromatograph is equipped with a conductivity detector, a 4-mm cation suppressor and a 4.6-mm × 25-cm column that contains packing L1. The flow rate is about 1.5 mL per minute. The flow rate for the cation suppressor is about 2 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative retention times are given in
Table 1; the ratio of the height of the vecuronium bromide related compound F peak to the height of the valley between the vecuronium bromide related compound F peak and the pancuronium bromide peak is not less than 2.0; and the relative standard deviation for replicate injections is not more than 10.0% for each compound.
[NoteThe system may need equilibration for 4 hours.
]
Procedure
Separately inject equal volumes (about 25 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the peak responses. Calculate the percentage of each vecuronium bromide related compound in the portion of Vecuronium Bromide taken by the formula:
2500(C/W)(rU / rS),
in which
C is the concentration, in mg per mL, of the relevant USP Reference Standard in the
Standard solution; W is the weight, in mg, of Vecuronium Bromide taken to prepare the
Test solution; and
rU and
rS are the peak areas for the correspondent vecuronium bromide related compound obtained from the
Test solution and
Standard solution, respectively: the limits of impurities are specified in
Table 1.
[NOTEUse the peak area of vecuronium bromide in the
Standard solution as
rS to calculate any unknown impurity.
]
Table 1
Compound Name |
Relative Retention Time |
Limit % |
Pancuronium bromide |
about 0.5 |
0.5 |
Vecuronium bromide related compound F1 |
about 0.6 |
0.5 |
Vecuronium bromide related compound C2 |
about 0.86 |
0.5 |
Vecuronium bromide |
1.0 |
|
Vecuronium bromide related compound A3 |
about 2.0 |
0.3 |
Vecuronium bromide related compound B4 |
about 2.6 |
0.5 |
Unknown |
|
0.1 |
Total |
|
1.0 |
1
3-deacetyl vecuronium bromide, (Piperidinium, 1-[(2 ,3 ,5 ,16 ,17 )-17-acetyloxy-3-hydroxy-2-(1-piperidinyl)androstan-16-yl]-1-methyl bromide)
2
3,17-Bis deacetyl vecuronium bromide; (Piperidinium, 1-[(2 ,3 ,5 ,16 ,17 )-3,17-dihydroxy-2-(1-piperidinyl)androstan-16-yl]-1-methyl bromide)
3
Dipiperidino diol diacetate; (3 ,17 -diacetyl-oxy-2 ,16 -bispiperidinyl-5 -androstan)
4
17-deacetyl vecuronium bromide; (Piperidinium, 1-[(2 ,3 ,5 ,16 ,17 )-3-acetyloxy-17-hydroxy-2-(1-piperidinyl)androstan-16-yl]-1-methyl bromide)
|
Assay
Solution A
Transfer 8.0 g of sodium perchlorate to a 1000-mL volumetric flask, dissolve in 6.0 mL of water, dilute with acetonitrile to volume, mix, filter, and degas.
Solution B
Transfer 3.2 g of ammonium chloride to a 2000-mL volumetric flask, dissolve in 16 mL of ammonium hydroxide, dilute with methanol to volume, mix, filter, and degas. [NOTEAvoid excessive degassing to prevent the loss of ammonium hydroxide.].
Mobile phase
Prepare a mixture of
Solution A and
Solution B (3:2). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Diluent
Pipet 1.0 mL of 1 N hydrochloric acid into a 1000-mL volumetric flask, dilute with acetonitrile to volume, and mix.
Standard preparation
Dissolve an accurately weighed quantity of
USP Vecuronium Bromide RS in
Diluent to obtain a solution having a known concentration of about 0.5 mg per mL.
Assay preparation
Transfer about 50 mg of Vecuronium Bromide, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with Diluent, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 215-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L3. The flow rate is about 0.5 mL per minute. The column temperature is maintained at 40
. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the column efficiency is not less than 5000 theoretical plates; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
34H
57BrN
2O
4 in the portion of Vecuronium Bromide taken by the formula:
100C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Vecuronium Bromide RS in the
Standard preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.