Identification
A:
Heat a quantity of finely powdered Tablets, equivalent to about 500 mg of niacin, with 25 mL of alcohol on a steam bath for a few minutes, filter, and wash the residue with a few mL of hot alcohol. To the filtrate add 30 mL of water, and evaporate to about 25 mL on the steam bath. Cool, filter if insoluble matter separates, and evaporate the filtrate to about 10 mL. Cool, and place in a refrigerator for 1 hour. Filter the separated niacin with suction, wash it with a few mL of cold alcohol, and dry at 105
for 1 hour: the niacin so obtained responds to
Identification tests
A and
B under
Niacin.
B:
The retention time of the major peak in the chromatogram of the
Assay preparation corresponds to that in the chromatogram of the
Standard preparation obtained as directed in the
Assay.
Dissolution 711
Medium:
0.1 N hydrochloric acid; 900 mL.
Apparatus 1:
100 rpm.
Time:
60 minutes.
Procedure
Determine the amount of C
6H
5NO
2 dissolved from UV absorbances at the wavelength of maximum absorbance at about 260 nm of filtered portions of the solution under test, suitably diluted with
Medium, if necessary, in comparison with a Standard solution having a known concentration of about 0.02 mg of
USP Niacin RS per mL in the same medium.
Tolerances
Not less than 65% (Q) of the labeled amount of C6H5NO2 is dissolved in 60 minutes.
Assay
Mobile phase
Prepare a 0.005
M solution of sodium 1-hexanesulfonate in water. Mix 78 parts of this solution with 14 parts of methanol, 7 parts of acetonitrile, and 1 part of glacial acetic acid, stir, filter, and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Transfer an accurately weighed quantity of
USP Niacin RS to a suitable volumetric flask, add water, heat on a steam bath, sonicate, shake by mechanical means, cool, and dilute with water to volume to obtain a solution having a known concentration of about 0.5 mg per mL. Transfer 1.0 mL of this solution to a 10-mL volumetric flask, dilute with water to volume, and mix.
Assay preparation
Weigh and finely powder not less than 20 Tablets. Transfer an accurately weighed quantity of the powder equivalent to about 500 mg of Niacin to a 100-mL volumetric flask, add 50 mL of water, and heat on a steam bath for 30 minutes. Sonicate for 2 minutes, shake by mechanical means for 15 minutes, and cool to room temperature. Dilute with water to volume, mix, and filter. Transfer 1.0 mL of this solution to a 100-mL volumetric flask, dilute with water to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 262-nm detector and a 4-mm × 30-cm column that contains packing L1. The flow rate is about 1.3 mL per minute. Chromatograph replicate injections of the
Standard preparation, and record the peak responses as directed for
Procedure: the column efficiency determined from the analyte peak is not less than 1000 theoretical plates, the tailing factor for the analyte peak is not more than 2.0, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
[NOTEUse peak areas where peak responses are indicated.
] Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
6H
5NO
2 in the portion of Tablets taken by the formula:
10,000C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Niacin RS in the
Standard preparation, and
rU and
rS are the peak responses for niacin obtained from the
Assay preparation and the
Standard preparation, respectively.