Limit of isomalathion
Mobile phase
Prepare a suitable degassed solution of methanol and water (50:30). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Isomalathion RS in methanol to obtain a solution having a known concentration of about 0.1 mg per mL.
Test preparation
Dissolve an accurately weighed quantity of Malathion in methanol to obtain a solution having a known concentration of about 20 mg per mL.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 210-nm detector and a 4-mm × 30-cm column that contains 10-µm packing L1. The flow rate is about 1 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative retention times are about 0.5 for isomalathion and 1.0 for malathion; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Test preparation into the chromatograph, record the chromatograms, and measure the responses of the major peaks. Calculate the percentage of isomalathion in the Malathion taken by the formula:
(CS / CU)(P)(rU / rS),
in which
CS is the concentration, in mg per mL, of
USP Isomalathion RS in the
Standard preparation; CU is the concentration, in mg per mL, of specimen in the
Test preparation; P is the stated purity, in percentage, of the
USP Isomalathion RS; and
rU and
rS are the isomalathion peak responses obtained from the
Test preparation and the
Standard preparation, respectively: not more than 0.3% of isomalathion is found.
Assay
Mobile phase
Prepare a suitable degassed solution of methanol and water (50:30). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Internal standard solution
Dissolve propylparaben in Mobile phase to obtain a solution containing about 0.6 mg per mL.
Standard preparation
Transfer about 100 mg of
USP Malathion RS, accurately weighed, to a 10-mL volumetric flask, add 1.0 mL of
Internal standard solution, dilute with methanol to volume, and mix.
Assay preparation
Transfer about 500 mg of Malathion, accurately weighed, to a 50-mL volumetric flask, add 5.0 mL of Internal standard solution, dilute with methanol to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 254-nm detector and a 4-mm × 30-cm column that contains 10-µm packing L1. The flow rate is about 1 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative retention times are about 0.6 for propylparaben and 1.0 for malathion; and the resolution,
R, of the propylparaben and malathion peaks is not less than 4, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
10H
19O
6PS
2 in the portion of Malathion taken by the formula:
50C(RU /RS),
in which
C is the concentration, in mg per mL, of
USP Malathion RS in the
Standard preparation; and
RU and
RS are the ratios of the peak responses of malathion to propylparaben obtained from the
Assay preparation and the
Standard preparation, respectively.