U.S. PHARMACOPEIA

Search USP29  
Helium
He 4.0026

Helium.
Helium [7440-59-7].
» Helium contains not less than 99.0 percent, by volume, of He.
Packaging and storage— Preserve in cylinders.
NOTE—Reduce the container pressure by means of a regulator. Measure the gases with a gas volume meter downstream from the detector tube in order to minimize contamination or change of the specimens.
(Postponed indefinitely)USP29
Identification— The flame of a burning splinter of wood is extinguished when inserted into an inverted test tube filled with Helium. [NOTE—Use caution.] A small balloon filled with Helium shows decided buoyancy.
Odor— Carefully open the container valve to produce a moderate flow of gas. Do not direct the gas stream toward the face, but deflect a portion of the stream toward the nose: no appreciable odor is discernible.
Carbon monoxide— Pass 1000 ± 50 mL through a carbon monoxide detector tube (see under Reagents in the section Reagents, Indicators, and Solutions) at the rate specified for the tube: the indicator change corresponds to not more than 0.001%.
Air— Not more than 1.0% of air is present, determined as directed in the Assay.
Change to read:
Assay— Introduce a specimen of Helium into a gas chromatograph by means of a gas sampling valve. Select the operating conditions of the gas chromatograph such that the standard peak signal resulting from the following procedure corresponds to not less than 70% of the full-scale reading. Preferably, use an apparatus corresponding to the general type in which the column is 4 mm in inside diameter and 6 m in length and is packed with porous polymer beads, which permits complete separation of nitrogen and oxygen from Helium, although the nitrogen and oxygen may not be separated from each other. Use industrial grade helium (99.99%) as the carrier gas, with a thermal-conductivity detector, and control the column temperature: the peak response produced by the assay specimen exhibits a retention time corresponding to that produced by USP Air–Helium RS,USP29 and indicates not more than 1.0% of air when compared to the peak response of the USP Air–Helium RS,USP29 and not less than 99.0%, by volume, of He.
(Postponed indefinitely)USP29
Auxiliary Information— Staff Liaison : Kahkashan Zaidi, Ph.D., Senior Scientific Associate
Expert Committee : (AER05) Aerosols05
USP29–NF24 Page 1045
Pharmacopeial Forum : Volume No. 31(4) Page 1077