Identification
A:
It meets the requirements of the test for Melting range.
B:
Thin-Layer Chromatographic Identification Test 201
Test solution:
a solution in methylene chloride containing about 50 mg per mL.
Developing solvent:
a mixture of ether and hexane (70:30).
Spray reagent:
a solution containing 20 mg of rhodamine B in 200 mL of alcohol.
Procedure
Proceed as directed in the chapter. Spray with the Spray reagent, and locate the spots on the plate by examination under UV light at a wavelength of 365 nm: the principal spot obtained from the Test solution corresponds in color, size, and RF value to that obtained from the Standard solution.
Limit of nickel
[CautionWhen using closed high-pressure digestion vessels and microwave laboratory equipment, be familiar with the safety and operating instructions given by the manufacturer.]
Magnesium nitrate solution
Transfer 2.5 g of magnesium nitrate to a 500-mL volumetric flask, and dissolve in and dilute with water to volume.
Test solution
Transfer an accurately weighed quantity of about 0.1 g of Glyceryl Distearate into a suitable high-pressure resistant digestion vessel (fluoropolymer or quartz), and add 6.0 mL of nitric acid and 2.0 mL of 30% hydrogen peroxide. Place the closed vessel in a laboratory microwave oven, and digest using an appropriate program (e.g., 250 W for 10 minutes; 600 W for 5 minutes; 400 W for 5 minutes; and 250 W for 7 minutes.) Allow the digestion vessel to cool before opening. Quantitatively transfer the contents to a 25-mL volumetric flask, dilute with water to volume, and mix.
Blank solution
Add 6.0 mL of nitric acid and 2.0 mL of 30% hydrogen peroxide to a high-pressure-resistant digestion vessel and proceed as directed for the Test solution.
Calibration solutions
Transfer 5.0 mL of nickel standard solution TS to a 10-mL volumetric flask, add 0.5 mL of nitric acid and 1.0 mL of 30 percent hydrogen peroxide, and dilute with water to volume (stock solution). Into four identical 25-mL volumetric flasks, each containing 6 mL of nitric acid, transfer respectively 20, 50, 100, and 150 µL of the stock solution obtained above, and dilute with water to volume. These solutions contain 4 ng per mL, 10 ng per mL, 20 ng per mL, and 30 ng per mL of nickel, respectively.
Zero solution
Transfer 6.0 mL of nitric acid to a 25-mL volumetric flask, add a small amount of water, mix, and then dilute with water to volume.
Procedure
Into seven separate 25-mL flasks, each containing 5.0 mL of
Magnesium nitrate solution, transfer respectively 10.0 mL of each of the following: the
Test solution, the
Blank solution, the four
Calibration solutions, and the
Zero solution. Concomitantly determine the absorbances of these solutions at least three times each, at the wavelength of maximum absorbance at 232.0 nm, with a suitable atomic absorption spectrophotometer (see
Spectrophotometry and Light-Scattering 851) equipped with a pyrolytically coated tube with a platform, a graphite furnace, and a nickel hollow-cathode lamp. Maintain the drying temperature of the furnace at 100
for 10 seconds after a 10-second ramp, the ashing temperature at 1400
for 10 seconds after a 20-second ramp, and the atomization temperature at 2500
for 5 seconds. Use the
Zero solution to set the instrument to zero. Record the average of the steady readings for each of the solutions
[NOTEIf necessary, dilute the
Test solution with the
Zero solution to obtain a reading within the calibrated absorbance range
]: not more than 1 µg per g is found.
Limit of free glycerin
Mobile phase and Chromatographic system
Proceed as directed in the Assay.
Standard solutions
Prepare four solutions by dissolving accurately weighed quantities of glycerin in tetrahydrofuran, and diluting each with tetrahydrofuran, as necessary, to obtain solutions having known concentrations of about 0.2, 0.4, 1.0, and 2.0 mg per mL.
Test solution
Use the Assay preparation, prepared as directed in the Assay.
Procedure
Separately inject equal volumes (about 40 µL) of the
Standard solutions and the
Test solution into the chromatograph, record the chromatograms, and measure the responses for the glycerin peaks. Plot the glycerin peak responses obtained versus the concentration, in mg per mL, of glycerin in the
Standard solutions. From the standard curve so obtained, determine the glycerin concentration,
C, in mg per mL, in the
Test solution. Calculate the percentage of free glycerin in the portion of Glyceryl Distearate taken by the formula:
500(C/W),
in which
C is as obtained above; and
W is the amount, in mg, of Glyceryl Distearate taken to prepare the
Test solution: not more than 1.0% of free glycerin is found.
Assay
Mobile phase:
tetrahydrofuran.
Assay preparation
Transfer about 200 mg of Glyceryl Distearate, accurately weighed, to a 5-mL volumetric flask, dissolve in and dilute with tetrahydrofuran to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a refractive index detector and a 7.5-mm × 60-cm column containing 5-µm 100-
packing L21. The column and the detector temperatures are maintained at 40
. [
NOTETwo or three 7.5-mm × 30-cm L21 columns may be used in place of the one 60-cm column, provided that system suitability requirements are met; and the column temperature may be lowered to ambient temperature, although working at 40
provides stable separation conditions and ensures better sample solubility.] The flow rate is about 1 mL per minute. Chromatograph the
Assay preparation, and record the peak responses as directed for
Procedure: the relative retention times are about 1.0 for glycerin, 0.84 for monoglycerides, 0.78 for diglycerides, and 0.75 for triglycerides; the resolution,
R, between the diglycerides and monoglycerides is not less than 1.0; and the relative standard deviation for replicate injections determined from the monoglycerides peak is not more than 2.0%.
Procedure
Inject a volume (about 40 µL) of the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the percentage of monoglycerides, diglycerides, and triglycerides in the portion of Glyceryl Distearate taken by the formula:
100(ri / rs),
in which
ri is the individual peak response for the monoglycerides, diglycerides, and triglycerides, as appropriate; and
rs is the sum of the responses for all of the glyceride peaks.