Dissolution 711
Medium:
0.05 M pH 6.8 phosphate buffer; 900 mL.
Apparatus 2:
75 rpm.
Time:
30 minutes.
Determine the amount of C18H22O5S·C4H10N2 dissolved by employing the following method.
Diluent and Mobile phase
Proceed as directed in the
Assay.
System suitability solution
Transfer about 100 mg of 4¢-nitroacetophenone, accurately weighed, to a 100-mL volumetric flask, and dissolve in methanol, sonicating if necessary. Dilute with methanol to volume, and mix. Pipet 2 mL of this solution into a 250-mL volumetric flask, dilute with water to volume, and mix.
Standard solution
Dissolve an accurately weighed quantity of
USP Estropipate RS in
Diluent, sonicating if necessary, and dilute quantitatively with
Diluent to obtain a solution having a known concentration of about 1 mg per mL. Pipet 2 mL of this solution into a 100-mL volumetric flask, dilute with water to volume, and mix. Pipet 4 mL of the solution so obtained into a second 100-mL volumetric flask, add 8.0 mL of the
System suitability solution, dilute with water to volume, and mix.
Test solution
Transfer an accurately measured volume of a filtered portion of the solution under test, equivalent to about 20 µg of estropipate, to a 25-mL volumetric flask. Dilute with water to volume if the contents are less than the nominal volume of the flask, and mix.
Chromatographic system (see Chromatography 621)
Prepare as directed in the
Assay. To evaluate the system suitability requirements, use the
Standard solution.
Procedure
Separately inject equal volumes (about 300 µL) of the Standard solution and the Test solution into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity of C18H22O5S·C4H10N2 dissolved.
Tolerances
Not less than 80% (Q) of the labeled amount of C18H22O5S·C4H10N2 is dissolved in 30 minutes.
Uniformity of dosage units 905:
meet the requirements.
PROCEDURE FOR CONTENT UNIFORMITY
Diluent, Mobile phase, System suitability solution, Standard preparation, and Chromatographic system
Prepare as directed in the
Assay.
Test preparation
Transfer 1 Tablet to a 50-mL volumetric flask, add 20 mL of water, insert the stopper, and shake by mechanical means for about 30 minutes or until the Tablet disintegrates. Add 20 mL of methanol, insert the stopper, and shake by mechanical means for about 60 minutes. Dilute with Diluent to volume, and mix. Transfer an accurately measured volume of this stock solution, equivalent to about 0.25 mg of estropipate, to a 25-mL volumetric flask, dilute with Diluent to volume, and mix. Pass this solution through a solvent-resistant membrane filter having a 1-µm or finer porosity, discarding the first portion of the filtrate.
Procedure
Proceed as directed in the
Assay, except to use the
Test preparation instead of the
Assay preparation.
Assay
Diluent
Prepare a mixture of methanol and water (1:1).
Mobile phase
Dissolve 13.6 g of monobasic potassium phosphate in 1000 mL of water, and mix. Mix 600 mL of the resulting solution with 200 mL of methanol, add 200 mL of acetonitrile with stirring, and mix. Filter, and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Estropipate RS in
Diluent, sonicating if necessary, and dilute quantitatively with
Diluent to obtain a solution having a known concentration of about 1 mg per mL. Pipet 1.0 mL of this solution into a 100-mL volumetric flask, dilute with
Diluent to volume, and mix.
System suitability solution
Transfer about 100 mg of 4¢-nitroacetophenone, accurately weighed, to a 100-mL volumetric flask, and dissolve in methanol, sonicating if necessary. Dilute with methanol to volume, and mix. Pipet 5 mL of this solution into a 200-mL volumetric flask, dilute with Diluent to volume, and mix. Pipet 5 mL of the solution so obtained into a 25-mL volumetric flask, dilute with Standard preparation to volume, and mix.
Assay preparation
Transfer 20 Tablets to a 1000-mL volumetric flask, add 200 mL of water, insert the stopper, and shake by mechanical means for about 30 minutes or until the Tablets disintegrate completely. Add 200 mL of methanol, insert the stopper, and shake by mechanical means for about 60 minutes. Dilute with Diluent to volume, and mix. Transfer an accurately measured volume of this stock solution, equivalent to about 0.25 mg of estropipate, to a 25-mL volumetric flask, dilute with Diluent to volume, and mix. Pass this solution through a solvent-resistant membrane filter having a 1-µm or finer porosity, discarding the first portion of the filtrate.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 213-nm detector and a 4.6-mm × 25-cm column that contains packing L1. The flow rate is about 2 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.85 for 4
¢-nitroacetophenone and 1.0 for estropipate; the resolution,
R, between estropipate and 4
¢-nitroacetophenone is not less than 3.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 50 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of estropipate (C
18H
22O
5S·C
4H
10N
2) in each Tablet taken by the formula:
(25C/V)(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Estropipate RS in the
Standard preparation; V is the volume, in mL, of the stock solution taken to prepare the
Assay preparation; and
rU and
rS are the peak responses for estropipate obtained from the
Assay preparation and the
Standard preparation, respectively.