Procedure
Determine the amount of C
22H
26N
2O
4S·HCl dissolved from UV absorbances at the wavelength of maximum absorbance at about 240 nm using filtered portions of the solution under test, suitably diluted with water, if necessary, in comparison with a Standard solution having a known concentration of
USP Diltiazem Hydrochloride RS in the same
Medium.
Tolerances
Use the following acceptance criteria for the 30-minute time point: at S
1 no unit is more than
Q; at S
2 the average value is equal to or less than
Q, and no unit is greater than
Q + 10%; at S
3 the average value is equal to or less than
Q, and not more than 2 units are more than
Q + 10%, and no unit is more than
Q + 25%. Use the criteria in the
Acceptance Table under
Dissolution 711 for the 3-hour time point. Not more than 60%
(Q) of the labeled amount of C
22H
26N
2O
4S·HCl is dissolved in 30 minutes, and not less than 75%
(Q) is dissolved in 3 hours.