Packaging and storage
Preserve in tight cylinders, and avoid exposure to excessive heat.
Identification
The IR absorption spectrum of it, determined in a 10-cm cell with sodium chloride windows, at atmospheric pressure, exhibits maxima, among others, at the following wavelengths, in µm: 4.33 (m), 4.46 (m), 4.56 (m), 6.29 (m), 7.25 (m), 8.05 (s), 8.63 (s), 9.1 (vs), 10.7 (vs), 10.8 (vs), 11.2 (m), 11.3 (m), 13.1 (w), and 13.9 (w). The stronger maxima are best obtained at pressures less than 10 mm of mercury.
Chromatographic purity
In the chromatogram recorded for the
Assay, identify the peaks due to dichlorotetrafluoroethane and trichloromonofluoromethane from relative retention times observed on chromatographing the
Resolution preparation: the sum of these two peak areas is not greater than 0.2% of the total of all peak areas, and the sum of the areas of all peaks other than that for dichlorodifluoromethane is not greater than 0.4% of the total of all peak areas.
Inorganic chlorides
Place 5 mL of anhydrous methanol in a test tube, add 3 drops of a saturated solution of silver nitrate in anhydrous methanol, shake, and add 7 g of Dichlorodifluoromethane: no opalescence or turbidity is produced.
Assay
Resolution preparation
Introduce a liquid-phase mixture of dichlorodifluoromethane, dichlorotetrafluoroethane, and trichloromonofluoromethane into an evacuated headspace vial.
Assay preparation
Introduce the liquid phase of Dichlorodifluoromethane into an evacuated headspace vial.
Chromatographic system
(see
Chromatography 621)The gas chromatograph is equipped with a flame-ionization detector, a headspace sampler, and a 2-mm × 1.8-m stainless steel column containing 1% phase G25 on support S12. For the headspace sampler, the bath temperature is 100
, the valve/loop temperature is 105
, and the sampling time is 3 seconds.
[NOTEMake adjustments as necessary to optimize peak areas to record trace level impurities.
] The carrier gas is helium maintained at a flow rate of 20 mL per minute. The injection port and detector temperatures are maintained at 110
and 200
, respectively. The column temperature is programmed to rise from 70
at the time of injection to 170
at the rate of 10
per minute, after which it is maintained at 170
for 5 minutes. Inject the gas phase headspace
Resolution preparation and obtain the chromatogram as directed for
Procedure: the approximate relative retention times are 0.5 for dichlorodifluoromethane, 0.8 for dichlorotetrafluoroethane, and 1.0 for trichloromonofluoromethane; and the resolution,
R, between dichlorotetrafluoroethane and trichloromonofluoromethane is not less than 2.0.
Procedure
Inject the gas phase headspace Assay preparation into the chromatograph, record the chromatogram, and measure the peak areas. Calculate the percentage (a/a) of CCl2F2 in the portion of Dichlorodifluoromethane taken.