NOTEIn this chapter, unit and dosage unit are synonymous.
To ensure the consistency of dosage units, each unit in a batch should have a drug substance content within a narrow range around the label claim. Dosage units are defined as dosage forms containing a single dose or a part of a dose of drug substance in each unit.
The term uniformity of dosage unit is defined as the degree of uniformity in the amount of the drug substance among dosage units. Therefore, the requirements of this chapter apply to each drug substance being comprised in dosage units containing one or more drug substances, unless otherwise specified in the individual monograph.
The uniformity of dosage units can be demonstrated by either of two methods,
Content Uniformity or
Weight Variation (see
Table 1). The test for
Content Uniformity is based on the assay of the individual content of drug substance(s) in a number of individual dosage units to determine whether the individual content is within the limits set. The
Content Uniformity method may be applied in all cases. The test for
Content Uniformity is required for those dosage forms described in
(C1)(C6) below:
The test for Weight Variation is applicable for the following dosage forms:
(W1) |
solutions for inhalation that are packaged in glass or plastic ampuls and intended for use in nebulizers, and oral solutions packaged in unit-dose containers and into soft capsules; |
(W2) |
solids (including sterile solids) that are packaged in single-unit containers and contain no added substances, whether active or inactive; |
(W3) |
solids (including sterile solids) that are packaged in single-unit containers, with or without added substances, whether active or inactive, that have been prepared from true solutions and freeze-dried in the final containers and are labeled to indicate this method of preparation; and |
(W4) |
hard capsules, uncoated tablets, or film-coated tablets, containing 25 mg or more of a drug substance comprising 25% or more, by weight, of the dosage unit or, in the case of hard capsules, the capsule contents, except that uniformity of other drug substances present in lesser proportions is demonstrated by meeting Content Uniformity requirements. |
The test for
Content Uniformity is required for all dosage forms not meeting the above conditions for the
Weight Variation test. Alternatively, products listed in item (W4) above that do not meet the 25 mg/25% threshold limit may be tested for uniformity of dosage units by
Weight Variation instead of the
Content Uniformity test if the concentration relative standard deviation (RSD) of the drug substance in the final dosage units is not more than 2%, based on process validation data and development data. The concentration RSD is the RSD of the concentration per dosage unit (w/w or w/v), where concentration per dosage unit equals the assay result per dosage unit divided by the individual dosage unit weight. See the RSD formula in
Table 2.
Table 1. Application of Content Uniformity (CU) and Weight Variation (WV) Tests for Dosage Forms
CONTENT UNIFORMITY
Select not less than 30 units, and proceed as follows for the dosage form designated. Where the amount of drug substance in a single dosage unit differs from that required in the
Assay, adjust the degree of dilution of the solutions and/or the volume of aliquots so that the concentration of the drug substances in the final solution is of the same order as that obtained in the
Assay procedure; or, in the case of a titrimetric assay, use a titrant of a different concentration, if necessary, so that an adequate volume of titrant is required (see
Titrimetry 541); see also
Procedures under
Tests and Assays in the
General Notices and Requirements. If any such modifications are made in the
Assay procedure set forth in the individual monograph, make the appropriate corresponding changes in the calculation formula and titration factor.
Where a special Procedure for content uniformity is specified in the test for Uniformity of dosage units in the individual monograph, make any necessary correction of the results obtained as follows.
-
Prepare a composite specimen of a sufficient number of dosage units to provide the amount of specimen called for in the Assay in the individual monograph plus the amount required for the special Procedure for content uniformity in the monograph by finely powdering tablets or mixing the contents of capsules or oral solutions, suspensions, emulsions, gels, or solids in single-unit containers to obtain a homogeneous mixture. If a homogeneous mixture cannot be obtained in this manner, use suitable solvents or other procedures to prepare a solution containing all of the drug substance, and use appropriate aliquot portions of this solution for the specified procedures.
-
Assay separate, accurately measured portions of the composite specimen of capsules or tablets or suspensions or inhalations or solids in single-unit containers, both (a) as directed in the Assay, and (b) using the special Procedure for content uniformity in the monograph.
-
Calculate the weight of drug substance equivalent to 1 average dosage unit, by (a) using the results obtained by the Assay procedure, and by (b) using the results obtained by the special procedure.
-
Calculate the correction factor, F, by the formula:
F = W/P,
in which W is the weight of drug substance equivalent to 1 average dosage unit obtained by the Assay procedure, and P is the weight of drug substance equivalent to 1 average dosage unit obtained by the special procedure. If
is greater than 10, the use of a correction factor is not valid.
-
The correction factor is to be applied only if F is not less than 1.030 nor greater than 1.100, or not less than 0.900 nor greater than 0.970. If F is between 0.970 and 1.030, no correction is required.
-
If F lies between 1.030 and 1.100, or between 0.900 and 0.970, calculate the weight of drug substance in each dosage unit by multiplying each of the weights found using the special procedure by F.
Uncoated, Coated, or Molded Tablets, Capsules, Oral Solutions in Single-Unit Containers, Oral Suspensions or Oral Emulsions or Oral Gels in Single-Unit Containers, and Solids (including Sterile Solids) in Single-Unit Containers
Assay 10 units individually as directed in the
Assay in the individual monograph, unless otherwise specified in the
Procedure for content uniformity in the individual monograph. Calculate the acceptance value as directed below.
For oral solutions, oral suspensions, oral emulsions, or oral gels in single-unit containers, conduct the Assay on the amount of well-mixed material that drains from an individual container in not more than 5 seconds, or for highly viscous products, conduct the Assay on the amount of well-mixed material that is obtained by quantitatively removing the contents from an individual container, and express the results as the delivered dose.
Calculation of Acceptance Value
Calculate the acceptance value by the formula:
in which the terms are as defined in
Table 2.
Table 2
Variable |
Definition |
Conditions |
Value |
bar(X) |
Mean of individual contents (1, 2,
, n), expressed as a percentage of the label claim |
|
|
1, 2,
, n |
Individual contents of the units tested, expressed as a percentage of the label claim |
|
|
n |
Sample size (number of units in a sample) |
|
|
k |
Acceptability constant |
If n = 10, then k = |
2.4 |
|
|
If n = 30, then k = |
2.0 |
s |
Sample standard deviation |
|
|
RSD |
Relative standard deviation (the sample standard deviation expressed as a percentage of the mean) |
|
|
M (case 1) to be applied when T 101.5 |
Reference value |
If 98.5% bar(X) 101.5%, then |
M = bar(X)
(AV = ks) |
|
|
If bar(X) <98.5%, then |
M = 98.5%
(AV = 98.5 bar(X) + ks) |
|
|
If bar(X) >101.5%, then |
M = 101.5%
(AV = bar(X) 101.5 + ks) |
|
|
|
|
M (case 2) to be applied when T >101.5 |
Reference value |
If 98.5 bar(X) T, then |
M = bar(X)
(AV = ks) |
|
|
If bar(X) <98.5%, then |
M = 98.5%
(AV = 98.5 bar(X) + ks) |
|
|
If bar(X) >T, then |
M = T%
(AV = bar(X) T + ks) |
Acceptance value (AV) |
|
|
general formula:
(Calculations are specified above for the
different cases.) |
L1 |
Maximum allowed acceptance value |
|
L1 = 15.0 unless otherwise specified in the individual monograph |
L2 |
Maximum allowed range for deviation of each dosage unit tested from the calculated value of M |
On the low side, no dosage unit result can be less than (1 L2*0.01)M, while on the high side no dosage unit result can be greater than (1 + L2*0.01)M. (This is based on an L2 value of 25.0.) |
L2 = 25.0 unless otherwise specified in the individual monograph |
T |
Target test sample amount at time of manufacture. For purposes of this Pharmacopeia, unless otherwise specified in the individual monograph, T is 100.0%, and for manufacturing purposes, T is the manufacturer's approved target test amount value at the time of manufacture. |
|
|
Suppositories, Transdermal Systems, and Inhalations Packaged in Premetered Dosage Units
[NOTEAcceptance value calculations are not required for these dosage forms.] Assay 10 units individually as directed in the Assay in the individual monograph, unless otherwise specified in the Procedure for content uniformity.
WEIGHT VARIATION
Select not less than 30 dosage units, and proceed as follows for the dosage form designated. The result of the Assay, obtained as directed in the individual monograph, is designated as result A, expressed as % of label claim (see Calculation of the Acceptance Value). Assume that the concentration (weight of drug substance per weight of dosage unit) is uniform. [NOTESpecimens other than these test units may be drawn from the same batch for assay determinations.]
Uncoated or Film-Coated Tablets
Accurately weigh 10 tablets individually. Calculate the drug substance content, expressed as % of label claim, of each tablet from the weight of the individual tablet and the result of the Assay. Calculate the acceptance value.
Hard Capsules
Accurately weigh 10 capsules individually, taking care to preserve the identity of each capsule. Remove the contents of each capsule by a suitable means. Accurately weigh the emptied shells individually, and calculate for each capsule the net weight of its contents by subtracting the weight of the shell from the respective gross weight. Calculate the drug substance content, expressed as % of label claim, of each capsule from the net weight of the individual capsule content and the result of the Assay. Calculate the acceptance value.
Soft Capsules
Accurately weigh 10 intact capsules individually to obtain their gross weights, taking care to preserve the identity of each capsule. Then cut open the capsules by means of a suitable clean, dry cutting instrument such as scissors or a sharp open blade, and remove the contents by washing with a suitable solvent. Allow the occluded solvent to evaporate from the shells at room temperature over a period of about 30 minutes, taking precautions to avoid uptake or loss of moisture. Weigh the individual shells, and calculate the net contents. Calculate the drug substance content, expressed as % of label claim, in each capsule from the net weight of product removed from the individual capsules and the result of the Assay. Calculate the acceptance value.
Solids (Including Sterile Solids) in Single-Unit Containers
Proceed as directed for Hard Capsules, treating each unit as described therein. Calculate the acceptance value.
Oral Solutions Packaged in Single-Unit Containers
Accurately weigh the amount of liquid that drains in not more than 5 seconds from each of 10 individual containers. If necessary, compute the equivalent volume after determining the density. Calculate the drug substance content, expressed as % of label claim, in the liquid drained from each unit from the net weight of the individual container content and the result of the Assay. Calculate the acceptance value.
Calculation of Acceptance Value
Calculate the acceptance value as shown in
Content Uniformity, except that the individual contents of the units are replaced with the individual estimated contents defined below.
1, 2, ... , n |
= |
individual estimated contents
of the units tested, where
i = wi × A / bar(W) , |
w1, w2, ... , wn |
= |
individual weights of the units
tested, |
A |
= |
content of drug substance (% of
label claim) determined as
described in the Assay, and |
bar(W) |
= |
mean of individual weights
(w1, w2, ... , wn). |
Solutions for Inhalation Packaged in Glass or Plastic Ampuls and Intended for Use in Nebulizers
[NOTEAcceptance value calculations are not required for these dosage forms.] Accurately weigh 10 containers individually, taking care to preserve the identity of each container. Remove the contents of each container by a suitable means. Accurately weigh the emptied containers individually, and calculate for each container the net weight of its contents by subtracting the weight of the container from the respective gross weight. From the results of the Assay, obtained as directed in the individual monograph, calculate the drug substance content, expressed as % of label claim, in each of the containers.
CRITERIA
Apply the following criteria, unless otherwise specified in the individual monograph.
Uncoated, Coated, or Molded Tablets, Capsules, Oral Solutions in Single-Unit Containers, Oral Suspensions or Oral Emulsions or Oral Gels in Single-Unit Containers, and Solids (Including Sterile Solids) in Single-Unit Containers
The requirements for dosage uniformity are met if the acceptance value of the first 10 dosage units is less than or equal to L1%. If the acceptance value is greater than L1%, test the next 20 units and calculate the acceptance value. The requirements are met if the final acceptance value of the 30 dosage units is less than or equal to L1%, and no individual content of any dosage unit is less than (1 L2*0.01)M nor more than (1 + L2*0.01)M as specified in the Calculation of Acceptance Value under Content Uniformity or under Weight Variation. Unless otherwise specified in the individual monograph, L1 is 15.0 and L2 is 25.0.
Suppositories
Limit A (if the average of the limits specified in the potency definition in the individual monograph is 100.0 percent or less)
Unless otherwise specified in the individual monograph, the requirements for dosage uniformity are met if the amount of the drug substance in each of the 10 dosage units as determined from the
Content Uniformity method lies within the range of 85.0% to 115.0% of the label claim, and the RSD is less than or equal to 6.0%.
If 1 unit is outside the range of 85.0% to 115.0% of label claim, and no unit is outside the range of 75.0% to 125.0% of label claim, or if the RSD is greater than 6.0%, or if both conditions prevail, test 20 additional units. The requirements are met if not more than 1 unit of the 30 is outside the range of 85.0% to 115.0% of label claim, and no unit is outside the range of 75.0% to 125.0% of label claim and the RSD of the 30 dosage units does not exceed 7.8%.
Limit B (if the average of the limits specified in the potency definition in the individual monograph is greater than 100.0 percent)
-
If the average value of the dosage units tested is greater than or equal to the average of the limits specified in the potency definition in the individual monograph, the requirements are as specified under Limit A, except that the words label claim are replaced by the words label claim multiplied by the average of the limits specified in the potency definition in the monograph divided by 100.
-
If the average value of the dosage units tested is between 100 percent and the average of the limits specified in the potency definition in the individual monograph, the requirements are as specified under Limit A, except that the words label claim are replaced by the words label claim multiplied by the average value of the dosage units tested (expressed as a percent of label claim) divided by 100.
Transdermal Systems and Inhalations Packaged in Premetered Dosage Units
Limit A (if the average of the limits specified in the potency definition in the individual monograph is 100.0 percent or less)
Unless otherwise specified in the individual monograph, the requirements for dosage uniformity are met if the amount of the drug substance in not less than 9 of the 10 dosage units as determined from the
Content Uniformity method (or, in the case of solutions for inhalation packaged in glass or plastic ampuls and intended for use in nebulizers, from either the
Content Uniformity or the
Weight Variation method) lies within the range of 85.0% to 115.0% of label claim, and no unit is outside the range of 75.0% to 125.0% of label claim, and the RSD of the 10 dosage units is less than or equal to 6.0%.
If 2 or 3 dosage units are outside the range of 85.0% to 115.0% of label claim, but not outside the range of 75.0% to 125.0% of label claim, or if the RSD is greater than 6.0% or if both conditions prevail, test 20 additional units. The requirements are met if not more than 3 units of the 30 are outside the range of 85.0% to 115.0% of label claim and no unit is outside the range of 75.0% to 125.0% of label claim, and the RSD of the 30 dosage units does not exceed 7.8%.
Limit B
(if the average of the limits specified in the potency definition in the individual monograph is greater than 100.0 percent)
-
If the average value of the dosage units tested is 100.0 percent or less, the requirements are as in Limit A
-
If the average value of the dosage units tested is greater than or equal to the average of the limits specified in the potency definition in the individual monograph, the requirements are as specified under Limit A, except that the words label claim are replaced by the words label claim multiplied by the average of the limits specified in the potency definition in the monograph divided by 100.
-
If the average value of the dosage units tested is between 100 percent and the average of the limits specified in the potency definition in the individual monograph, the requirements are as specified under Limit A, except that the words label claim are replaced by the words label claim multiplied by the average value of the dosage units tested (expressed as a percent of label claim) divided by 100.