Chromatographic purity
Mobile phase, System suitability solution, Standard preparation, System sensitivity solution, and Chromatographic system
Proceed as directed in the Assay.
Test solution
Use the stock solution reserved from the Assay preparation.
Procedure
Inject a volume (about 10 µL) of the
Test solution into the chromatograph, record the chromatogram, and measure the peak responses. Calculate the percentage of each impurity in the volume of Injection taken by the formula:
100(ri /rs),
in which
ri is the peak response for each impurity, and
rs is the sum of the responses of all of the peaks: not more than 1.0% of any individual impurity is found, and not more than 1.5% of total impurities is found.
Assay
Mobile phase
Dissolve 2.0 g of monobasic potassium phosphate in 800 mL of water. Add 5 mL of 1.0
M tetrabutylammonium dihydrogen phosphate solution, dilute with water to 980 mL, and mix. Add 20 mL of acetonitrile, mix, filter, and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution
Dissolve accurately weighed quantities of
USP Adenosine RS and inosine in warm water (50
to 55
), and dilute quantitatively, and stepwise if necessary, with water to obtain a solution having known concentrations of about 0.03 mg each of adenosine and inosine per mL.
Standard preparation
Dissolve an accurately weighed quantity of
USP Adenosine RS in warm water (50
to 55
), and dilute quantitatively, and stepwise if necessary, with water to obtain a solution having a known concentration of about 0.03 mg per mL. If sodium chloride is present in the Injection, add 0.01 mL of sodium chloride solution (0.9 in 100) per mL of the anticipated final volume of the
Standard preparation before the addition of the warm water.
System sensitivity solution
Pipet 3.0 mL of the Standard preparation into a 200-mL volumetric flask, dilute with water to volume, and mix.
Assay preparation
Transfer an accurately measured volume of Injection, equivalent to about 30 mg of adenosine, to a 100-mL volumetric flask, dilute with water to volume, and mix. Reserve a portion of this stock solution for use in the test for Chromatographic purity. Pipet 5.0 mL of the stock solution into a 50-mL volumetric flask, dilute with water to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 2.5 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the tailing factor for the adenosine peak is not more than 2.0; and the resolution,
R, between adenosine and inosine is not less than 6.0. Similarly chromatograph the
Standard preparation: the relative standard deviation for replicate injections is not more than 1.5%. Chromatograph the
System sensitivity solution, and adjust the run time to 2½ times the retention time of adenosine.
Procedure
Separately inject equal volumes (about 10 µL) of the
Assay preparation and the
Standard preparation into the chromatograph, record the chromatograms, and measure the areas of the adenosine peak responses. Calculate the quantity, in mg, of adenosine (C
10H
13N
5O
4) in each mL of the Injection taken by the formula:
CD(rU /rS),
in which
C is the concentration, in mg per mL, of
USP Adenosine RS in the
Standard preparation; D is the concentration, in mg per mL, of adenosine in the
Assay preparation, based on the labeled quantity per mL and the extent of dilution; and
rU and
rS are the peak responses for adenosine obtained from the
Assay preparation and the
Standard preparation, respectively.