Ordinary impurities 466
Test solution:
dimethyl sulfoxide.
Standard solution:
dimethyl sulfoxide.
Eluant:
a mixture of chloroform, methanol, and ammonium hydroxide (80:20:2).
Visualization:
1.
Application volume:
5 µL.
Limit:
1%.
Change to read:
Assay and limit for guanine
Mobile phase
Prepare a filtered and degassed solution of glacial acetic acid in water (1 in 1000). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution 1
Dissolve accurately weighed quantities of
USP Acyclovir RS and guanine in 0.1 N sodium hydroxide, and dilute quantitatively, and stepwise if necessary, with water to obtain a solution having known concentrations of about 0.1 mg of each per mL.
System suitability solution 2
Dissolve an accurately weighed quantity of guanine in 0.1 N sodium hydroxide, and dilute quantitatively, and stepwise if necessary, with water to obtain a solution having a known concentration of about 0.7 µg per mL.
Guanine standard preparation
Transfer about 8.75 mg of guanine, accurately weighed, to a 500-mL volumetric flask. Dissolve in 50 mL of 0.1 N sodium hydroxide, dilute with water to volume, and mix. Transfer 2.0 mL of this solution to a 50-mL volumetric flask, dilute with 0.01 N sodium hydroxide to volume, and mix to obtain a solution having a concentration of about 0.7 µg per mL.
Standard preparation
Dissolve about 25 mg of
USP Acyclovir RS, accurately weighed, in 5 mL of 0.1 N sodium hydroxide in a 50-mL volumetric flask, dilute with water to volume, and mix. Transfer 10.0 mL of this solution to a 50-mL volumetric flask, dilute with 0.01 N sodium hydroxide to volume, and mix to obtain a solution having a known concentration of about 0.1 mg of
USP Acyclovir RS per mL.
Assay preparation
Dissolve about 100 mg of Acyclovir, accurately weighed, in 20 mL of 0.1 N sodium hydroxide in a 200-mL volumetric flask, dilute with water to volume, and mix. Transfer 10.0 mL of this solution to a 50-mL volumetric flask, dilute with 0.01 N sodium hydroxide to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a
4.6-mm × 25-cm
USP29 column that contains packing L1. The flow rate is about 3 mL per minute. Chromatograph
System suitability solution 1, and record the peak responses as directed for
Procedure: the resolution,
R, between acyclovir and guanine is not less than 2.0; the tailing factor for the analyte peak is not more than 2; and the relative standard deviation for replicate injections for the acyclovir peak is not more than 2.0%. Chromatograph
System suitability solution 2, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation, the
Guanine standard preparation, and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for all the peaks. Calculate the quantity, in µg, of guanine in the portion of Acyclovir taken by the formula:
1000C(rU / rS)
in which
C is the concentration, in µg per mL, of guanine in the
Guanine standard preparation; and
rU and
rS are the peak responses due to guanine in the
Assay preparation and the
Guanine standard preparation, respectively: not more than 0.7% of guanine is found. Calculate the quantity, in mg, of C
8H
11N
5O
3 in the portion of Acyclovir taken by the formula:
1000C(rU / rS)
in which
C is the concentration, in mg per mL, of
USP Acyclovir RS in the
Standard preparation; and
rU and
rS are the peak responses due to acyclovir in the
Assay preparation and the
Standard preparation, respectively.