Chromatographic purity
Mobile phase
Prepare a filtered and degassed mixture of 0.5% trifluoroacetic acid, tetrahydrofuran, acetonitrile, and methanol (13.5:3:3:1). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard solution
Dissolve an accurately weighed quantity of
USP Trazodone Hydrochloride RS in
Mobile phase, and dilute quantitatively, and stepwise if necessary, with
Mobile phase to obtain a solution having a known concentration of about 2 µg per mL.
System suitability solution
Dissolve suitable quantities of 3-chloroaniline and
USP Trazodone Hydrochloride RS in
Mobile phase to obtain a solution containing about 0.1 mg per mL of 3-chloroaniline and 0.01 mg per mL of trazodone hydrochloride, respectively.
Test solution
Transfer about 50 mg of trazodone hydrochloride, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and filter.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 248-nm detector and a 4.6-mm × 15-cm column that contains 3-µm packing L7. The flow rate is about 1.0 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.6 for 3-chloroaniline and 1 for trazodone hydrochloride, and the resolution,
R, between 3-chloroaniline and trazodone hydrochloride, is not less than 12. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the tailing factor for the analyte peak is not more than 2.0, and the relative standard deviation for replicate injections is not more than 5%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the responses for all of the peaks. Calculate the percentage of each peak, other than the trazodone hydrochloride peak, in the Trazodone Hydrochloride taken by the formula:
100(CS / CT)(rU / rS),
in which
CS is the concentration, in mg per mL, of
USP Trazodone Hydrochloride RS in the
Standard solution,
CT is the concentration, in mg per mL, of trazodone hydrochloride in the
Test solution,
rU is the response of each peak, other than the trazodone hydrochloride peak, obtained from the
Test solution, and
rS is the peak response for trazodone hydrochloride obtained from the
Standard solution: not more than 0.4% for any single impurity and not more than 1.0% of total impurities are found.
Ordinary impurities 466
Test solution:
methanol.
Standard solution:
methanol.
Eluant:
a mixture of cyclohexane, acetone, and ammonium hydroxide (8:4.5:0.5).
Visualization:
1.
Assay
0.01 M Ammonium phosphate buffer
Transfer 1.15 g of monobasic ammonium phosphate to a 1000-mL volumetric flask, and dissolve in water. Add 1.0 mL of 1 N sodium hydroxide, dilute with water to volume, and mix. Adjust this solution, if necessary, with either 10% phosphoric acid or 1 N sodium hydroxide to a pH of 6.0 ± 0.1, and filter.
Mobile phase
Prepare a filtered and degassed mixture of methanol and
0.01 M Ammonium phosphate buffer (60:40). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Internal standard solution
Dissolve a suitable quantity of butylparaben in methanol to obtain a solution containing about 2 mg per mL.
Standard preparation
Dissolve an accurately weighed quantity of
USP Trazodone Hydrochloride RS in
Mobile phase to obtain a solution having a known concentration of about 2.5 mg per mL. Transfer 4.0 mL of this solution to a 100-mL volumetric flask, add 2.0 mL of
Internal standard solution, dilute with
Mobile phase to volume, and mix to obtain a solution having a known concentration of about 0.1 mg of
USP Trazodone Hydrochloride RS per mL.
Assay preparation
Transfer an accurately weighed quantity of about 125 mg of Trazodone Hydrochloride to a 50-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix. Transfer 4.0 mL of this solution to a 100-mL volumetric flask, add 2.0 mL of the Internal standard solution, dilute with Mobile phase to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 1.5 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the resolution,
R, between the trazodone and butylparaben peaks is not less than 3.0, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 25 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. The relative retention times are about 0.6 for butylparaben and 1.0 for trazodone. Calculate the quantity, in mg, of C
19H
22ClN
5O·HCl in the portion of Trazodone Hydrochloride taken by the formula:
1250C(RU / RS),
in which
C is the concentration, in mg per mL, of
USP Trazodone Hydrochloride RS in the
Standard preparation, and
RU and
RS are the ratios of the peak responses of the trazodone to the internal standard obtained from the
Assay preparation and the
Standard preparation, respectively.