Assay
Proceed as directed under
AntibioticsMicrobial Assays 81, using an accurately weighed portion of Ointment shaken with about 50 mL of ether in a separator, and extracted with four 20-mL portions of
Buffer No. 1. Combine the buffer extracts, and dilute with
Buffer No. 1 to an appropriate volume to obtain a stock solution. Add sufficient 0.01 N hydrochloric acid to an accurately measured portion of the stock solution so that the amount of hydrochloric acid in the
Test Dilution will be the same as in the median dose level of the Standard, and quantitatively dilute with
Test Dilution having a bacitracin concentration assumed to be equal to the median dose level of the Standard.