Packaging and storage
Preserve in single-dose or multiple-dose containers that previously have been treated to prevent adsorption.
Labeling
Label it to include the following: the time and date of calibration; the amount of 32P as phosphate expressed in total megabecquerels (microcuries or millicuries) and in megabecquerels (microcuries or in millicuries) per mL at the time of calibration; the name and quantity of any added preservative or stabilizer; a statement of the intended use, whether oral or intravenous; a statement of whether the contents are intended for diagnostic or therapeutic use; the expiration date; and the statements CautionRadioactive Material, and Not for intracavitary use. The labeling indicates that in making dosage calculations, correction is to be made for radioactive decay, and also indicates that the radioactive half-life of 32P is 14.3 days.
Radionuclide identification
A:
The beta radiation of the Solution, measured according to the procedure set forth under
Radioactivity 821, shows a mass absorption coefficient within ±5% of the value found for a specimen of a known standard of the same radionuclide when determined under identical counting conditions and geometry.
B:
Its beta-ray and/or bremsstrahlung spectrum is identical to that of a specimen of 32P of known purity showing no distinct photopeaks and no energies greater than 1.710 MeV.
Bacterial endotoxins 85
It contains not more than 175/
V USP Endotoxin Unit per mL of the Injection, when compared with the USP Endotoxin RS, in which
V is the maximum recommended total dose, in mL, at the expiration date or time.
Radiochemical purity
Place a measured volume, appropriately diluted with phosphoric acid solution (1 in 20) such that it provides a count rate of about 20,000 counts per minute, about 45 mm from the end of a 25- × 300-mm strip of chromatographic paper (see
Chromatography 621), and allow to dry. Develop the chromatogram by descending chromatography, using a mixture of tertiary butyl alcohol, water, and formic acid (40:20:5). Allow to dry, and determine the position of the phosphoric acid by spraying the paper with a solution prepared by dissolving 5 g of ammonium molybdate in 100 mL of water and pouring, with constant stirring, into a mixture of 12 mL of nitric acid and 24 mL of water. Determine the position of the radioactivity distribution by scanning with a collimated radiation detector. The radioactivity appears in one band only, corresponding in
RF value to the phosphoric acid.
Other requirements
Solution intended for intravenous use meets the requirements under
Injections 1, except that the Solution may be distributed or dispensed prior to completion of the test for
Sterility, the latter test being started on the day of final manufacture, and except that it is not subject to the recommendation on
Volume in Container.
Assay for radioactivity
Using a suitable counting assembly (see
Assay,
Beta-emitting under
Radioactivity 821), determine the radioactivity, in MBq (mCi) per mL, of Solution by use of a calibrated system as directed under
Radioactivity 821).