Nicotine release
Transfer an accurately weighed quantity of Nicotine Polacrilex, equivalent to about 4 mg of nicotine, to a glass-stoppered test tube, add 10.0 mL of sodium chloride solution (0.9 in 100) that has been warmed to 37
, and shake by mechanical means for 10 minutes. Immediately pass the liquid through a dry filter paper, discarding the first mL of the filtrate. Transfer 1.0 mL of the filtrate to a 25-mL volumetric flask, dilute with 0.1 N hydrochloric acid to volume, and mix. Determine the absorbances of the solution in a 1-cm cell at 236 nm and 282 nm and at the wavelength of maximum absorbance at about 259 nm, using 1.0 mL of sodium chloride solution (0.9 in 100) diluted to 25 mL with 0.1 N hydrochloric acid as the blank. Calculate the percentage of nicotine released by the formula:
(77400 /
CW)(
A259 0.5
A236 0.5
A282),
in which 77400 is a specific absorbance and dilution factor;
C is the percentage of nicotine in the Nicotine Polacrilex on the basis of the amount determined in the
Assay; W is the weight, in mg, of the Nicotine Polacrilex taken; and
A259,
A236, and
A282 are the absorbances of the solution under test, corrected for the blank absorbances, at the wavelengths indicated by the subscripts: not less than 70% is released in 10 minutes.
Water, Method I 921
Transfer about 1.0 g of Nicotine Polacrilex, accurately weighed, to a 50-mL glass-stoppered test tube, add 20.0 mL of methanol, shake for 30 minutes, and allow to stand for about 30 minutes. Use a 10-mL portion of the methanol layer for the titration: not more than 5.0% is found.
Chromatographic purity
Mobile phase and Chromatographic system
Proceed as directed in the Assay.
Standard solution
Transfer 1.0 mL of the Standard preparation, prepared as directed in the Assay, to a 100-mL volumetric flask, dilute with Mobile phase to volume, and mix.
Test solution
Use the Assay preparation.
Procedure
[NOTEUse peak areas where peak responses are indicated.
] Separately inject equal volumes (about 20 µL) of the
Standard solution and the
Test solution into the chromatograph, and allow the chromatograms to run for not less than two times the retention time of the major peak. Record the chromatograms, and measure the peak responses. Calculate the percentage of each impurity in the portion of Nicotine Polacrilex taken by the formula:
(162.23/462.41)(100/3)(100C / W)(ri / rS),
in which 162.23 and 462.41 are the molecular weights of nicotine and anhydrous nicotine bitartrate, respectively,
C is the concentration, in mg per mL, of
USP Nicotine Bitartrate Dihydrate RS on the anhydrous basis in the
Standard solution,
W is the weight, in mg, of nicotine in the Nicotine Polacrilex taken, and
ri and
rS are peak responses for the individual impurity and nicotine bitartrate dihydrate obtained from the
Test solution and the
Standard solution, respectively: not more than 0.3% of any individual impurity is found, and the sum of all impurities is not more than 1.0%.
Assay
0.25 M Sodium dodecyl sulfate
Dissolve 18.02 g of sodium dodecyl sulfate in 25 mL of glacial acetic acid and sufficient water to make 250 mL, and mix.
Mobile phase
Mix 640 mL of water, 50 mL of 1 M sodium acetate, and 40 mL of
0.25 M Sodium dodecyl sulfate, and filter. Add 270 mL of acetonitrile, mix, and degas. Adjust the amount of water if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Nicotine Bitartrate Dihydrate RS in 1 M ammonium hydroxide to obtain a solution having a known concentration of about 6 mg per mL. Transfer 3.0 mL of this solution to a 10-mL volumetric flask, add 3 mL of 1 M acetic acid, dilute with water to volume, and mix.
Assay preparation
Transfer an accurately weighed quantity of Nicotine Polacrilex, equivalent to about 20 mg of nicotine, to a glass-stoppered test tube. Add 10.0 mL of 1 M ammonium hydroxide, shake for 10 minutes, and centrifuge. Transfer 3.0 mL of the clear solution to a 10-mL volumetric flask, add 3 mL of 1 M acetic acid, and dilute with water to volume. [NOTERetain the resin residue from centrifugation for use in Identification test B.]
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column containing packing L1. The flow rate is about 2.0 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the tailing factor is not more than 2.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the areas of the major peaks. Calculate the percentage of nicotine (C
10H
14N
2) in the portion of Nicotine Polacrilex taken by the formula:
100(162.23 / 462.41)(100C / 3W)(rU / rS),
in which 162.23 and 462.41 are the molecular weights of nicotine and anhydrous nicotine bitartrate, respectively;
C is the concentration, in mg per mL, of
USP Nicotine Bitartrate Dihydrate RS on the anhydrous basis in the
Standard preparation; W is the weight, in mg, of the portion of Nicotine Polacrilex taken; and
rU and
rS are the peak areas obtained from the
Assay preparation and the
Standard preparation, respectively.