Assay
Buffer solution
Dissolve 1.80 g of anhydrous sodium acetate in 1 L of water. Adjust, if necessary, with glacial acetic acid to a pH of 4.5 ± 0.2.
Mobile phase
Prepare a filtered and degassed mixture of
Buffer solution and acetonitrile (86:14). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve about 20 mg of
USP Methazolamide RS, accurately weighed, in 20 mL of acetonitrile contained in a 200-mL volumetric flask. Dilute with
Buffer solution to volume, and mix. Quantitatively dilute an accurately measured volume of this solution with
Buffer solution to obtain a solution having a known concentration of about 50 µg of
USP Methazolamide RS per mL.
Resolution solution
Prepare a solution of acetaminophen and
USP Methazolamide RS in acetonitrile containing 0.3 mg of acetaminophen and 0.5 mg of methazolamide per mL. Quantitatively dilute an accurately measured volume of this solution with
Buffer solution to obtain a solution containing 30 µg of acetaminophen and 50 µg of methazolamide per mL.
Assay preparation
Transfer about 100 mg of Methazolamide, accurately weighed, to a 200-mL volumetric flask, dissolve in 20 mL of acetonitrile, dilute with Buffer solution to volume, and mix. Quantitatively dilute an accurately measured volume of this solution with Buffer solution to obtain a solution having a known concentration of about 50 µg per mL.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 265-nm detector and a 3.9-mm × 15.0-cm column containing packing L1. The flow rate is about 1.5 mL per minute. Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.6 for acetaminophen and 1.0 for methazolamide, the resolution,
R, between the acetaminophen peak and the methazolamide peak is not less than 4.0, and the tailing factor is not more than 2.0. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 2%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the areas of the responses for the major peaks. Calculate the quantity, in mg, of C
5H
8N
4O
3S
2 in the portion of Methazolamide taken by the formula:
2C(rU / rS),
in which
C is the concentration, in µg per mL, of
USP Methazolamide RS in the
Standard preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.