Identification
A: Ultraviolet-Visible Absorption 197U
Spectral range:
300 to 700 nm.
Solution
Prepare as directed below for the Test solution in the test for Content of lycopene.
Ratio:
A476 / A508, between 1.10 and 1.14.
B:
The retention time of the major peak in the chromatogram of the Test solution corresponds to that in the chromatogram of the Standard solution, as obtained in the test for Content of all-E-lycopene, 5Z-lycopene, and related compounds.
Content of all-E-lycopene, 5Z-lycopene, and related compounds
Mobile phase
Prepare a filtered and degassed mixture of
tert-butyl methyl ether, methanol, and tetrahydrofuran (784:665:74). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard solution
Dissolve a suitable quantity of
USP Lycopene RS in
Mobile phase to obtain a solution containing about 2 mg per 100 mL.
Test solution
Transfer about 15 mg of Lycopene to a 25-mL volumetric flask, and dissolve in tetrahydrofuran containing 50 mg of butylated hydroxytoluene per L. Dilute with the same solvent to volume. Pipet 2 mL into a 50-mL volumetric flask, and add 8 mL of tetrahydrofuran. Dilute with tert-butyl methyl ether to volume. Use this solution for injection.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 472-nm detector, a 4.6-mm × 25-cm column that contains 5-µm packing L62, and a second column connected in series containing 3-µm packing L62. The flow rate is about 1.0 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative retention times are about 1.07 for 5
Z-lycopene, and 1.0 for all-
E-lycopene; the resolution,
R, between all-
E-lycopene and 5
Z-lycopene is not less than 1.0; the tailing factor is not less than 0.8 and not more than 2.0; and the relative standard deviation for replicate injections for the all-
E-lycopene is not more than 2.0 %.
[NOTENew columns may require up to 30 injections before the system suitability requirements are met.
]
Procedure
Inject about 10 µL of the
Test solution into the chromatograph, record the chromatogram, and measure the peak area responses. Calculate the percentage of related compounds in the portion of Lycopene taken by the formula:
T(rs / rT),
in which
T is the percentage of total lycopene isomers obtained in the test for
Content of lycopene; rs is the sum of the responses of all peaks except the peak for all-
E-lycopene and the peak for 5
Z-lycopene; and
rT is the total detected area. Not more than 9.0% of other related compounds calculated as lycopene are found. Calculate the percentage of the 5
Z-lycopene isomer in the portion of Lycopene taken by the formula:
T(r5Z / rT),
in which
r5Z is the peak response for the 5
Z-lycopene isomer, and the other terms are as described above. Not more than 23.0% of the 5
Z-lycopene isomer is found. Calculate the percentage of all-
E-lycopene taken by the formula:
T(rE / rT),
in which
rE is the peak response of the all-
E-lycopene isomer, and the other terms are as described above. Not less than 70.0% of all-
E-lycopene is found.
Content of lycopene
Test stock solution
Transfer about 25 mg of Lycopene to a 100-mL volumetric flask, add about 25 mg of butylated hydroxytoluene and about 60 mL of methylene chloride, and sonicate to dissolve. Dilute with methylene chloride to volume.
Test solution
Transfer 2.0 mL of the Test stock solution to a 200-mL volumetric flask, and dilute with cyclohexane to volume.
Procedure
Determine the absorbance of the
Test solution at the wavelength of maximum absorbance at about 476 nm, using cyclohexane as the blank. Calculate the percentage of C
40H
56 in the portion of Lycopene taken by the formula:
1000A/331W,
in which
A is the absorbance of the
Test solution; W is the weight, in g, of Lycopene taken to prepare the
Test stock solution; and 331 is the absorptivity of the pure lycopene in cyclohexane.