Packaging and storage
Preserve in tight glass containers, protected from light. Store at room temperature.
Identification
A:
Dissolve about 500 mg of Maleic Acid in 10 mL of water: the pH of the solution is not less than 2.
B:
The principal spot in the chromatogram obtained from Test solution 2 corresponds in color, size, and RF value to that in the chromatogram obtained from the Maleic acid standard solution, as obtained in the test for Limit of fumaric acid.
C:
Dissolve about 35 mg of resorcinol in 10 mL of sulfuric acid (Resorcinol solution). Dissolve about 100 mg of Maleic Acid in 10 mL of water (Test solution). To 0.3 mL of the Test solution add 3 mL of the Resorcinol solution, and heat in a water bath for 15 minutes: no color develops. To 3 mL of the Test solution add 1 mL of bromine TS, heat in a water bath for 15 minutes to remove the bromine, then heat to boiling, and cool. To 0.2 mL of this solution, add 3 mL of the Resorcinol solution, and heat in a water bath for 15 minutes: a violet-pink color develops.
Color and clarity of solution
Dilute hydrochloric acid solution
Mix 27.5 mL of hydrochloric acid with sufficient water to make 1000 mL.
Reference solution
Mix 2.4 mL of ferric chloride CS and 0.6 mL of cobaltous chloride CS with Dilute hydrochloric acid solution to make 10 mL. Dilute 5 mL of this solution with Dilute hydrochloric acid solution to make 100 mL.
Test solution
Dissolve about 5 g of Maleic Acid in 50 mL of water.
Procedure
Place the
Reference solution and the
Test solution in matched color-comparison tubes, and compare the solutions by viewing them downward against a white surface (see
Color and Achromicity 631): the
Test solution is clear and not more intensely colored than the
Reference solution.
Heavy metals, Method II 231
Test solution
Transfer 1.0 g of Maleic Acid to a quartz crucible, add 0.5 g of magnesium oxide, and mix. Ignite the crucible to dull redness until a homogeneous white or grayish-white mass is obtained. Ignite at 800
for 1 hour, cool, and dissolve the residue by adding two 5-mL portions of diluted hydrochloric acid. Add 0.1 mL of phenolphthalein TS, and then add ammonium hydroxide until a pink color is obtained. Cool, add glacial acetic acid until the solution is decolorized, then add 0.5 mL of glacial acetic acid in excess, and dilute with water to 20.0 mL.
Standard solution
To 0.5 g of magnesium oxide, add 1.0 mL of
Standard Lead Solution, and evaporate to dryness at 105
for 1 hour. Following the procedure described above for preparation of the
Test solution, ignite, dissolve in diluted hydrochloric acid, add ammonia and then acetic acid, and dilute with water to 20.0 mL.
Procedure
To 12 mL of the Test solution, add 2.0 mL of pH 3.5 Acetate Buffer, mix, add to 1.2 mL of thioacetamideglycerin base TS, and mix immediately. To 10 mL of the Standard solution, add 2.0 mL of the Test solution and 2.0 mL of pH 3.5 Acetate Buffer, mix, add 1.2 mL of thioacetamideglycerin base TS, and mix immediately. Prepare a blank, using a mixture of 10 mL of water and 2.0 mL of the Test solution. Compared to the blank, the solution obtained from the Standard solution shows a light brown color. Dilute each of the solutions obtained from the Test solution and the Standard solution with water to 50 mL, allow to stand for 2 minutes, and view downward over a white surface. The color of the solution obtained from the Test solution is not darker than that of the solution obtained from the Standard solution: not more than 10 µg per g.
Limit of fumaric acid
Adsorbent:
0.25-mm layer of chromatographic silica gel mixture.
Test solution 1
Dissolve an accurately weighed quantity of Maleic Acid in acetone to obtain a solution having a concentration of about 100 mg per mL.
Test solution 2
Transfer about 1.0 mL of Test solution 1 to a 50-mL volumetric flask, dilute with acetone to volume, and mix.
Maleic acid standard solution
Dissolve an accurately weighed quantity of
USP Maleic Acid RS in acetone to obtain a solution having a known concentration of about 2 mg per mL.
Fumaric acid standard solution
Dissolve an accurately weighed quantity of
USP Fumaric Acid RS in acetone to obtain a solution having a known concentration of about 1.5 mg per mL.
Resolution solution
Prepare a mixture of Maleic acid standard solution and the Fumaric acid standard solution (1:1).
Developing solvent system
Prepare a mixture of heptane, butanol, chloroform, and anhydrous formic acid (44:36:16:16).
Procedure
Proceed as directed for
Thin-Layer Chromatography under
Chromatography 621, using an unsaturated chamber. Separately apply 10 µL of the
Resolution solution and 5 µL each of
Test solution 1, Test solution 2, the
Maleic acid standard solution, and the
Fumaric acid standard solution. Dry the plate at 100
for 15 minutes, and examine the plate under short-wavelength UV light at 254 nm. The chromatogram obtained from the
Resolution solution exhibits two clearly separated spots, and any spot corresponding to fumaric acid in the chromatogram of
Test solution 1 does not exceed, in size or intensity, the principal spot obtained in the chromatogram of the
Fumaric acid standard solution: not more than 1.5% of fumaric acid is found.
Limit of iron
Diluted standard iron solution
Immediately before use, dilute 1 volume of the
Standard Iron Solution, prepared as directed under
Iron 241, with 9 volumes of water.
[NOTEThis solution contains the equivalent of 1 µg of iron per mL.
]
Potassium thiocyanate solution
Dissolve 9.7 g of potassium thiocyanate in 100 mL of water.
Test solution
Dissolve about 1 g of Maleic Acid, accurately weighed, in 10 mL of water. Add 2 mL of diluted hydrochloric acid and 0.05 mL of bromine TS. After 5 minutes, remove the excess of bromine with the aid of a current of air, add 3 mL of Potassium thiocyanate solution, and shake well.
Standard solution
To 5 mL of Diluted standard iron solution add 6 mL of water. Add 1 mL of diluted hydrochloric acid and 0.05 mL of bromine TS. After 5 minutes, remove the excess of bromine with the aid of a current of air, add 3 mL of Potassium thiocyanate solution, and shake well.
Procedure
Allow the Standard solution and the Test solution to stand for 5 minutes. Any red color in the Test solution is not more intense than that in the Standard solution: not more than 5 µg per g.
Residual solvents 467:
meets the requirements.
(Official January 1, 2007)
Assay
Dissolve about 500 mg of Maleic Acid, accurately weighed, in 50 mL of water, and titrate with 1 N sodium hydroxide VS, using
phenolphthalein TS as the indicator. Each mL of 1 N sodium hydroxide is equivalent to 58.04 mg of C
4H
4O
4.