Packaging and storage
Preserve in single-dose containers.
Labeling
Label it to include the following, in addition to the information specified for
Labeling under
Injections 1: the time and date of calibration; the amount of
111In as labeled pentetreotide complex expressed as total megabecquerels (or millicuries) and the concentration expressed as megabecquerels (or millicuries) per mL on the date and time of calibration; the expiration date; and the statement, CautionRadioactive Material. The labeling indicates that in making dosage calculations, correction is to be made for radioactive decay, and states that the radioactive half-life of
111In is 67.3 hours.
Bacterial endotoxins 85
It contains not more than 175/
V USP Endotoxin Unit per mL, in which
V is the maximum recommended total dose, in mL, at the expiration date or time.
Radiochemical purity
Solution A
Dissolve 6.8 g of sodium acetate in 500 mL of water. Adjust with glacial acetic acid to a pH of 5.5, dilute with water to 1000 mL, and mix. Filter through a filter having a porosity of 0.5 µm or less, and degas.
Solution B
Use methanol.
Mobile phase
Use variable mixtures of Solution A and Solution B as directed under Chromatographic system.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 3.9-mm × 30-cm stainless steel column that contains 10-µm packing L1. It is also equipped with a flow-through gamma-ray detector having a cell volume of about 50 µL and calibrated to provide a linear response within the range of 0.5 to 15 MBq (14 to 400 µCi). The column temperature is maintained at 35
. The chromatograph is programmed to provide variable mixtures of
Solution A and
Solution B, and the initial flow rate is about 1 mL per minute. The column is equilibrated for at least 15 minutes with a mobile phase consisting of 60%
Solution A and 40%
Solution B. After injection, the composition of the mobile phase is changed linearly to 20%
Solution A and 80%
Solution B at 20 minutes, then changed to 100%
Solution B over the next 0.1 minute, and is held at that percentage while the flow rate is increased linearly from 1 to 2 mL over the next 5 minutes, which is the end of the run. Counts are recorded and charted for 25 minutes at about 2-second intervals.
Procedure
Constitute the Injection, and allow to stand for 30 minutes. Inject a volume of Injection having an activity of 0.5 to 15 MBq (14 to 400 µCi) into the chromatograph, and record the chromatogram. The retention time of the
111In pentetreotide peak (which should elute as a double peak) is between 4 and 5 relative to that of unbound
111In. Record the counts for the
111In pentetreotide, unbound
111In, other impurity peaks, and a representative baseline segment, and calculate the percentage of radioactivity from
111In pentetreotide by the formula:
100P / (P + O),
in which
P is the count of the
111In pentetreotide peak, and
O is the count for all other peaks, each being corrected for its corresponding baseline count. The radioactivity of
111In pentetreotide is not less than 90% of the total radioactivity.
Radionuclidic purity 821
Using a suitable counting assembly (see
Selection of a Counting Assembly), determine the radioactivity of each radionuclidic impurity, in kBq per MBq (or µCi per mCi) of
111In, in the Injection by use of a calibrated system.
INDIUM
114mThe presence of 114mIn in the Injection is demonstrated by a characteristic gamma-ray spectrum with prominent photopeaks having energies of 0.192, 0.558, and 0.724 MeV. 114mIn decays with a radioactive half-life of 49.5 days. The amount of 114mIn is not greater than 3 kBq per MBq (3 µCi per mCi) of 111In.
ZINC
65The presence of 65Zn in the Injection is demonstrated by a characteristic gamma-ray spectrum with a prominent photopeak at 1.115 MeV. 65Zn decays with a radioactive half-life of 243.9 days. The amount of 65Zn is not greater than 3 kBq per MBq (3 µCi per mCi) of 111In.
Other requirements
It meets the requirements under
Injections 1, except that the Injection may be distributed or dispensed prior to the completion of the test for
Sterility 71, the latter test being started on the day of final manufacture, and except that it is not subject to the recommendation on
Volume in Container.