Packaging and storage
Preserve in tight containers, preferably hermetically sealed, and remote from fire.
Reaction
Shake 10 mL with 10 mL of water, both having been previously cooled to 0
, and allow the supernatant layer of ethyl chloride to volatilize spontaneously: the remaining liquid is neutral to litmus. Retain the liquid for the test for
Alcohol.
Alcohol
To the liquid obtained in the test for
Reaction add a few drops of
potassium dichromate TS and 2 mL of 2 N sulfuric acid, and boil the mixture: no odor of acetaldehyde is perceptible, and no greenish or purplish color is produced.
Limit of nonvolatile residue and odor
Allow 5 mL to evaporate spontaneously from a tared, shallow dish: no foreign odor is perceptible while the last portions evaporate, and the weight of the residue is negligible.
Chloride
Add a few drops of
silver nitrate TS to 10 mL of alcohol, cool to 0
, and add to the clear liquid about 500 µL of Ethyl Chloride cooled to the same temperature: no turbidity is produced immediately.
Assay
Introduce about 1.5 mL of cold Ethyl Chloride into a tared glass-stoppered pressure bottle containing 25.0 mL of 1 N alcoholic potassium hydroxide VS, rapidly replace the stopper, and weigh accurately. Tie down the stopper, insert the bottle in a wire basket, and immerse in a water bath at room temperature.
[CautionBefore raising the bath temperature, take adequate precautions to cover the bottle or erect a suitable safety shield to prevent injury in case the bottle should burst.
] Heat the water bath to boiling, maintain at this temperature for 30 minutes, and then cool gradually to room temperature before handling the bottle. Remove the stopper, add
phenolphthalein TS, and titrate the excess alkali with 1 N hydrochloric acid VS. Perform a blank determination (see
Residual Titrations 541). Each mL of 1 N alcoholic potassium hydroxide is equivalent to 64.51 mg of C
2H
5Cl.
Auxiliary Information
Staff Liaison :
Daniel K. Bempong, Ph.D., Scientist
Expert Committee : (MDPS05) Monograph Development-Pulmonary and Steroids
USP29NF24 Page 870
Pharmacopeial Forum : Volume No. 31(5) Page 1368
Phone Number : 1-301-816-8143