Chromatographic purity
Standard solutions
Dissolve
USP Dapsone RS in methanol and mix to obtain
Standard solution A having a known concentration of 12.5 mg per mL. Dilute quantitatively with methanol to obtain
Standard solution B, containing 125 µg of the USP Reference Standard per mL, and
Standard solution C, containing 62.5 µg of the USP Reference Standard per mL.
Test solution
Dissolve an accurately weighed quantity of Dapsone in methanol to obtain a solution containing 12.5 mg per mL.
Procedure
[NOTEPrepare the solvent system fresh daily. Equilibrate the chromatographic chamber with the solvent system for 30 minutes prior to development of the chromatographic plate.
] Separately apply 4 µL of the
Test solution and each of the
Standard solutions to a suitable high-performance thin-layer chromatographic plate (see
Chromatography 621) coated with a 150- to 200-µm layer of chromatographic silica gel. Dry the applications with the aid of a stream of nitrogen. Position the plate in a chromatographic chamber, and develop the chromatograms in a solvent system consisting of a mixture of chloroform, acetone,
n-butyl alcohol, and formic acid (60:15:15:10) until the solvent front has moved about three-fourths of the length of the plate. Remove the plate from the developing chamber and air-dry. Spray the plate lightly with a 0.1% (w/v) solution of 4-dimethylaminocinnamaldehyde in a mixture of equal volumes of glacial acetic acid and water. Examine the spots that are developed immediately, and compare the intensities of any secondary spots observed in the chromatogram of the
Test solution with those of the principal spots in the chromatogram of the
Standard solutions: no secondary spot from the chromatogram of the
Test solution is larger or more intense than the principal spot obtained from
Standard solution C (0.5%), and the sum of the intensities of all the secondary spots obtained from the
Test solution corresponds to not more than 1.0%.
Assay
Mobile phase
Transfer 100 mL of isopropyl alcohol, 100 mL of acetonitrile, and 100 mL of ethyl acetate to a 1000-mL volumetric flask. Add pentane to volume without mixing, then mix, and allow the mixture to cool to room temperature.
Standard preparation
Dissolve an accurately weighed quantity of
USP Dapsone RS in methanol to obtain a solution having a known concentration of about 250 µg per mL. Pipet 5 mL of this solution into a 50-mL volumetric flask, dilute with
Mobile phase to volume, and mix to obtain a
Standard preparation having a known concentration of about 25 µg per mL.
Assay preparation
Transfer about 50 mg of Dapsone, accurately weighed, to a 200-mL volumetric flask. Dissolve in methanol, dilute with methanol to volume, and mix. Pipet 5 mL of this solution into a 50-mL volumetric flask, dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The chromatograph is equipped with a 254-nm detector and a 4-mm × 30-cm column that contains 10-µm diameter packing L3. Chromatograph a sufficient number of injections of the
Standard preparation as directed for
Procedure: the relative standard deviation is not more than 2%.
Procedure
Separately introduce equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph by means of a suitable microsyringe or sampling valve, adjusting the specimen size and other operating parameters to obtain satisfactory chromatograms. Measure the responses for the major peaks obtained at corresponding retention times with the
Assay preparation and the
Standard preparation. Calculate the quantity, in mg, of C
12H
12N
2O
2S in the portion of Dapsone taken by the formula:
2C(PU / PS),
in which
C is the concentration, in µg per mL, of
USP Dapsone RS in the
Standard preparation; and
PU and
PS are the peak responses obtained from the
Assay preparation and the