Packaging and storage
Preserve in tight, light-resistant containers.
Identification
Its IR absorption spectrum, obtained by spreading a capillary film of it between sodium chloride plates, exhibits maxima at 2800 cm
1 (broad); 2950 cm
1 (broad); at 1730 cm
1 (medium, sharp); at 1270 cm
1 (medium, sharp); and at 710 cm
1 (medium, sharp).
Viscosity 911
Transfer about 500 mL to a tall-form, 600-mL beaker, and adjust the temperature to 25 ± 0.1
. Using a suitable rotational viscosimeter with a spindle having a cylinder 5.63 cm in diameter and 2.25 cm high attached to a shaft 0.32 cm in diameter, the distance from the top of the cylinder to the lower tip of the shaft being 2.91 cm, and the immersion depth being 6.11 cm (No. 1 spindle), operate the viscosimeter at 100 rpm for 60 seconds, accurately timed, and record the scale reading. Convert the scale reading to centipoises by multiplying by the constant for the spindle and speed employed. The average of three viscosities obtained is no more than 100 centipoises.