Limit of free ethylene oxide and dioxane
CautionEthylene oxide is toxic and flammable. Prepare all solutions in a well-ventilated hood. The operator must protect hands and face by wearing polyethylene protective gloves and an appropriate face mask. Store all solutions in hermetic containers, and refrigerate at a temperature between 4 and 8.
NOTEPerform all determinations three times.
Ethylene oxide stock solution
Into a dry, clean test tube, cooled in a mixture of 1 part of sodium chloride and 3 parts of crushed ice, introduce a slow current of ethylene oxide gas, allowing condensation onto the inner wall of the test tube. Using a glass syringe, previously cooled to
10
, transfer about 300 µL of liquid ethylene oxide, equivalent to about 0.25 g, to 50 mL of polyethylene glycol 200. Determine the absorbed quantity of ethylene oxide by weighing before and after absorption. Dilute with polyethylene glycol 200 to 100.0 mL, and mix. This is the
Ethylene oxide stock solution.
Transfer 10.0 mL of magnesium chloride solution, prepared by adding 5 g of magnesium chloride to 10 mL of alcohol, to a volumetric flask. Add 20.0 mL of 0.1 M alcoholic hydrochloric acid VS. Insert the stopper, shake to obtain a saturated solution, and allow to equilibrate overnight. Transfer 5.00 mL of Ethylene oxide stock solution, accurately measured, to the flask, and allow to stand for 30 minutes. Titrate with 0.1 M alcoholic potassium hydroxide VS, determining the endpoint potentiometrically. Perform a blank titration, using the same quantity of polyethylene glycol 200 instead of Ethylene oxide stock solution, and note the difference in volumes required. Each mL of the difference in volumes of 0.1 M alcoholic potassium hydroxide VS consumed is equivalent to 4.404 mg of ethylene oxide. Calculate the concentration of ethylene oxide, in mg per g, in the Ethylene oxide stock solution.
Ethylene oxide solution
Quantitatively dilute a volume of Ethylene oxide stock solution, accurately measured, with polyethylene glycol 200 to obtain a solution containing about 50 µg of ethylene oxide per g. Dilute 1.0 mL of this solution with water to 5.0 mL to obtain a solution having a known concentration of about 10 µg of ethylene oxide per mL. [NOTEPrepare immediately before use.]
Dioxane stock solution
Dissolve about 1.00 g of dioxane, accurately weighed, in water, and dilute quantitatively, and stepwise if necessary, with water to obtain a solution having a known concentration of about 1.0 mg per mL.
Dioxane solution
Quantitatively dilute a volume of the Dioxane stock solution, accurately measured, with water to obtain a solution having a known concentration of about 0.5 mg of dioxane per mL.
Standard solution 1
Transfer about 1.0 g of the substance under test, accurately weighed, to a 10-mL vial, and add 1.0 mL of
N,N-dimethylacetamide, 0.1 mL of
Ethylene oxide solution, and 0.1 mL of
Dioxane solution. Close the vial, and mix to obtain a homogenous solution. Allow to stand at 90
for 45 minutes.
Standard solution 2
Transfer 0.1 mL of Ethylene oxide solution to a 10-mL vial, add 0.1 mL of a freshly prepared solution of acetaldehyde, containing about 10 mg of acetaldehyde per L, and add 0.1 mL of Dioxane solution. Close the vial, and mix to obtain a homogenous solution.
Test solution
Transfer about 1.0 g of the substance under test, accurately weighed, to a 10-mL vial, and add 1.0 mL of
N,N-dimethylacetamide and 0.2 mL of water. Close the vial, and mix to obtain a homogenous solution. Allow to stand at 90
for 45 minutes.
Chromatographic system (see Chromatography 621)
[NOTEHeadspace apparatus that automatically transfers a measured amount of headspace may be used.
] The gas chromatograph is equipped with a flame-ionization detector and contains a 0.32-mm × 30-m glass or quartz capillary column bonded with a 1.0-µm layer of phase G1. The carrier gas is helium, flowing at a rate of about 1 mL per minute. The detector and injection port temperatures are maintained at 250
and 150
, respectively. The column temperature is programmed as follows. Initially it is maintained at 50
for 5 minutes after injection, then increased to 180
at a rate of 5
per minute, further increased to 230
at a rate of 30
per minute, and maintained at this temperature for 5 minutes. Chromatograph the gaseous phase of
Standard solution 2, and record the peak responses as directed for
Procedure, adjusting the sensitivity of the system so that the peak heights of the two principal peaks in the chromatogram are not less than 15% of the full scale of the recorder: the relative retention times are about 0.94 for acetaldehyde and 1.0 for ethylene oxide; the resolution,
R, between acetaldehyde and ethylene oxide is not less than 2.0; and the relative standard deviation for replicate injections is not more than 15.0%.
Procedure
Using a heated, gas-tight gas chromatographic syringe, separately inject equal volumes (about 1 mL) of the gaseous headspace of
Standard solution 1 and the
Test solution into the chromatograph, record the chromatograms, and measure the peak responses: the mean areas of the ethylene oxide and dioxane peaks in the chromatogram obtained from the
Test solution are not greater than half the mean areas of the corresponding peaks in the chromatogram obtained from
Standard solution 1, equivalent to about 1 µg of ethylene oxide per g and 50 µg of dioxane per g. Calculate the concentration of ethylene oxide, in µg per g, in the test specimen taken by the formula:
CrU /(
rS MU rU MS),
in which
C is the concentration, in µg per mL, of ethylene oxide in
Standard solution 1; rU and
rS are the peak responses of ethylene oxide obtained from the
Test solution and
Standard solution 1, respectively; and
MU and
MS are the quantities, in g, of the substance under test taken to prepare the
Test solution and
Standard solution 1, respectively: not more than 1 µg per g is found. Calculate the concentration of dioxane, in µg per g, in the test specimen taken by the formula:
CD dU / 5(
dS MU dU MS),
in which
CD is the concentration, in µg, of dioxane in
Standard solution 1; dU and
dS are the peak responses of dioxane obtained from the
Test solution and
Standard solution 1, respectively; and
MU and
MS are as defined above: not more than 10 µg per g is found.
Limit of free glycerol
Dissolve 1.20 g of the substance under test in 25 mL of methylene chloride, heating if necessary. Cool, and add 100 mL of water and 25.0 mL of periodic acid solution, prepared by dissolving 150 mg of periodic acid in 25 mL of water. Shake, and allow to stand for 30 minutes. Add 40 mL of potassium iodide solution, prepared by dissolving 3 g of potassium iodide in 40 mL of water, and allow to stand for 1 minute. Add 1 mL of starch TS, and titrate the liberated iodine with 0.1 M sodium thiosulfate. Perform a blank determination, and make any necessary correction (see
Titrimetry 541). Each mL of 0.1 M sodium thiosulfate is equivalent to 2.3 mg of glycerol: not more than 5.0% is found.