Procedure
Prepare a 15-mm × 170-mm chromatographic tube with a 4-mm × 50-mm outlet by packing it, in increments, with
Support Phase, firmly tamping down each increment, until the tube is filled to a height of about 10 cm. In a beaker, prepare a mixture of 1 g of acid-washed chromatographic siliceous earth for column chromatography and 1 mL of
Test Solution. Transfer the mixture to the top of the column. Dry-wash the beaker with
Support Phase, and transfer to the column to provide an additional 1-cm layer on top of the mixture containing the
Test Solution. Within 30 minutes, pass chloroform through the column, and collect successive fractions of 5.0 mL, 5.0 mL, 10.0 mL, 10.0 mL, and 5.0 mL. Observe the column during elution, and note the appearance of two separate yellow bands. The fraction or fractions containing the first yellow band contain the anhydrotetracyclines. Discard these fractions. The fractions after the first yellow band contain the 4-epianhydrotetracycline. Determine the absorbance of each 4-epianhydrotetracycline fraction at the wavelength of maximum absorbance at about 438 nm, with a suitable spectrophotometer, diluting each fraction, if necessary, with chloroform, and using chloroform as the blank. Calculate the quantity, in mg, of 4-epianhydrotetracycline in each fraction by the formula:
AVD/20.08,
in which
A is the absorbance,
V is the volume, in mL, of the fraction taken,
D is the dilution factor, if the fraction was diluted, and 20.08 is the absorptivity of 4-epianhydrotetracycline at 438 nm. From the sum of the quantities of 4-epianhydrotetracycline found in the fractions, calculate the percentage of 4-epianhydrotetracycline in relation to the tetracycline hydrochloride equivalent contained in the
Test Solution.